Play all audios:
Download PDF Article Open access Published: 13 June 2019 Spin Seebeck mechanical force Kazuya Harii1,2, Yong-Jun Seo2, Yasumasa Tsutsumi3, Hiroyuki Chudo1, Koichi Oyanagi ORCID:
orcid.org/0000-0001-8784-078X4, Mamoru Matsuo3,5, Yuki Shiomi3,6,7, Takahito Ono8, Sadamichi Maekawa1,3,5 & …Eiji Saitoh1,2,4,7 Show authors Nature Communications volume 10, Article number:
2616 (2019) Cite this article
7403 Accesses
34 Citations
42 Altmetric
Metrics details
Subjects Magnetic devicesSpintronics AbstractElectric current has been used to send electricity to far distant places. On the other hand, spin current, a flow of electron spin, can in principle also send angular momentum to distant
places. In a magnet, there is a universal spin carrier called a spin wave, a wave-type excitation of magnetization. Since spin waves exhibit a long propagation length, it should be able to
send angular momentum that can generate torque and force at a distant place: a new function of magnets. Here we observe mechanical angular momentum transmission and force generation due to
spin waves injected into Y3Fe5O12 by the spin-Seebeck effect. The spin-wave current, transmitted through a Y3Fe5O12 micro cantilever, was found to create a mechanical force on the cantilever
as a non-local reaction of the spin-Seebeck effect. Spin-wave current can be generated remotely even in open circuits, and it can be used to drive micro mechanical devices.
Similarcontent being viewed by others Measurement of spin–orbit torque using field counterbalancing in radial current geometry Article Open access 08 November 2023 Spin–orbit torque switching of a
ferromagnet with picosecond electrical pulses Article 26 October 2020 A spin–orbit torque device for sensing three-dimensional magnetic fields Article 15 February 2021 Introduction
In 1915, Einstein and de Haas reported that an object starts rotating when it is magnetized: the Einstein-de Haas effect1,2,3. They explained the effect in terms of angular momentum
conservation between magnetization and mechanical motion. A similar effect may arise from ferromagnetic resonance (FMR), where a magnet is rotated by a reaction of magnetization damping4,5.
However, entire torque created by the Einstein-de Hass effect is limited by total spins in a sample, a situation which has made its application difficult. On the other hand, recently
discovered spin-wave current6,7,8 can create a continuous flow of angular momentum9, which makes it possible to inject unlimited total angular momentum into a matter10.
The spin-Seebeck effect (SSE)11,12,13,14 is a practical way to generate such a powerful spin-wave current; when a part of a sample is heated, spin waves are created and flow out of the part.
According to an analysis of SSE15, SSE can create much greater flux of angular momentum than the standard spin-pumping methods16, since SSE drives a broader energy range of spin waves17,18
than spin pumping.
Here we show that spin waves transmit angular momentum and create force to drive mechanical motion in an insulating magnet. In the present study, spin waves are injected into a small
magnetic insulator Y3Fe5O12 (YIG). When the spin waves are relaxed in a part of the magnet, there should be its reaction on the magnet; due to the angular momentum conservation between spin
waves and the lattice system of the magnet, the part of the magnet may start rotating (see Fig.1). Observing this unexplored spin-mechanical torque is our target in the present
study.
Fig. 1Schematic illustration of spin Seebeck mechanical force. a A schematic illustration of spin Seebeck effects. When a part of a magnetic insulator is heated, a spin wave is excited and flows
out of the part: the spin-wave spin Seebeck effect. A spin wave carries angular momentum. b Relaxation of spin waves generates macroscopic mechanical torque and force due to the angular
momentum transfer
Full size imageResultsSample description and characterizationFigure 2a, b shows a schematic illustration and a scanning electron microscope (SEM) image of an YIG cantilever used in the present study. The mechanical torque is observed as force acting
on a micro-cantilever, one of the most sensitive force detectors19,20,21,22. When mechanical torque along the y axis acts on the cantilever, as shown in Fig. 2a, the cantilever bends along
the z axis. The cantilever was fabricated by a focused-ion-beam (FIB) technique from a single-crystalline YIG with 3-µm-thick on a Gd3Ga5O12 (GGG) substrate23 (see “Methods” for details).
The length, width, and thickness of the cantilever arm are 200, 3.5, and 1.6 μm, respectively. We put a thin heater wire on the bulk joint part made of YIG to which the cantilever is
connected, as shown in Fig. 2c. By applying current pulses to the heater, the YIG joint is locally heated, creating spin waves. The spin waves then flow into the cantilever as a spin-wave
current, a phenomenon called the spin-wave SSE, and it is expected to generate torque via the spin-wave relaxation in the cantilever. The distance between the wire and the cantilever, 3.8
μm, is shorter than the spin-diffusion length of spin waves in YIG, 8.7 μm3.
Fig. 2Sample system. a A schematic illustration of the sample used in the present study. The sample consists of a cantilever made of Y3Fe5O12(YIG) connected to an edge of a YIG film and a heater
placed on the YIG film around the root of the cantilever. An electric current applied to the heater generates heat, which flows across the YIG film and the GGG substrate toward the sample
holder. The heat current creates spin-wave (magnon) accumulation at the surface and the bottom of the YIG film. The accumulation injects spin current into the YIG cantilever connected around
the surface of the film. b A scanning electron beam microscope (SEM) image of the YIG cantilever used in the present study. The heater wire is connected to a current source via the
electrode pad. c A magnified view around the root of the cantilever. d A block diagram of the measurement system. Vertical fluctuation of the tip of the cantilever is measured by using a
laser-Doppler interferometer. An a.c. heat with the frequency fH is generated by applying an a.c. current with the frequency fH/2. An a.c. magnetic field with the frequency F is applied
simultaneously. e A schematic illustration of the control sample, in which a trench filled with carbon was introduced between the heater and the cantilever (the black bar in the Figure). f A
SEM image around the root of the control sample
Full size imageIn Fig. 3a, we show the amplitude of cantilever fluctuation as a function of its frequency f measured without any external excitation to oscillation; the amplitude is simply due to thermal
fluctuation. In the spectrum, a broad peak around f0 = 22.8 kHz appears. f0 is consistent with the numerically calculated frequency of the fundamental vibration of the cantilever (see
Supplementary Note 1 for details). At the frequencies inside the broad peak, significant thermal fluctuation of the cantilever is always excited due to the room temperature heat, which means
that, inside the peak, the cantilever is quite sensitive to external force due to the mechanical resonance. Taking advantage of the sensitivity, we performed dual-frequency a.c.
measurements22 by applying a.c. spin-wave currents with the frequencies within the broad peak to detect spin-wave mechanical force (see “Methods” for details).
Fig. 3Amplitude of cantilever fluctuation d as a function of fluctuation frequency f. a Background thermal fluctuation. The spectrum was obtained without any external excitation. A broad peak
around 22.8 kHz is the fundamental thermal vibration of the cantilever induced just by heat. b Fluctuation spectrum obtained with an a.c. current and an a.c. field perpendicular to the
cantilever. The frequencies of the current fH/2 and the field F are 9.8960 kHz and 3.0010 kHz, respectively. A sharp peak is labeled as Δ. c Fluctuation spectrum obtained for the control
sample with an a.c. current and an a.c. field perpendicular to the cantilever. The frequencies of the current fH/2 and the field F are 10.4272 and 3.0500 kHz, respectively. d Fluctuation
spectrum obtained with an a.c. field parallel to the cantilever and an a.c. current. The frequency of the current fH/2 and the field F are 9.9038 and 3.0010 kHz, respectively. e Fluctuation
spectrum obtained with an a.c. field perpendicular to the cantilever without current. The frequency of the field is 3.0010 kHz. f Fluctuation spectrum obtained with an a.c. current without
fields. The frequency of the current is 9.8960 kHz
Full size imageCantilever fluctuation measurementsWe then applied heat pulses (a.c. heat) to the sample with the repetition frequency fH = 19.792 kHz. Surprisingly, a clear sharp peak emerges at 22.793 kHz in the amplitude spectrum (shown
as Δ in Fig. 3b) signaling unconventional cantilever motion superimposed on the broad thermal background peak. In the measurement, the external a.c. magnetic field is applied perpendicular
to the cantilever with the modulation frequency F = 3.0010 kHz. The frequency at which the sharp peak Δ appears fp = 22.793 kHz coincides with the frequency sum fH + F, showing that the
sharp peak Δ is due to cantilever motion synchronized with the heat-current pulses created in the cantilever. In all measurements, the d.c. component of the magnetic field is zero.
The sharp peak Δ has nothing to do with the conventional thermal expansion or distortion, but it is attributed to the spin-wave angular momentum transfer. We fabricated a sample in which a
cantilever is magnetically isolated from the spin-wave injector but it is thermally coupled24, which we call the control sample. Figure 2e is a schematic illustration of the control sample:
the root of the YIG cantilever is replaced with nonmagnetic carbon, which conducts heat well but blocks out spin waves. Because the thermal conductivity of carbon is comparable to that of
YIG25,26, the control sample exhibits similar thermal properties to the YIG cantilever. Nevertheless, in the control sample, no sharp peaks are observed in the amplitude spectra even when
the same heat pulses and fields are applied, while the broad peak corresponding to the background thermal vibration is almost unchanged as shown in Fig. 3c. The result indicates that the
cantilever motion at the sharp peak is driven by the torque magnetically transmitted through the cantilever, ruling out phonon mediated effects as well as thermal stress. The similar
behavior is observed in other samples, showing the universality of the present effect (see Supplementary Note 2 for details).
To double-check the spin-wave angular momentum transfer, we confirmed that the sharp peak Δ completely disappears when the magnetization of the YIG is directed parallel to the cantilever
length by applying a field along the x direction, as shown in Fig. 3d. Since the angular momentum carried by the spin waves is directed along the magnetization, the fundamental vibration of
the cantilever cannot be excited by the spin-wave angular momentum when the magnetization is along the cantilever length, which is consistent with the observed magnetization-direction
dependence. We also confirmed that the sharp peak Δ disappears when either the external a.c. field or the heat pulses are switched off, as shown in Fig. 3e, f.
Current and fielddependence of cantilever fluctuation
The amplitude of the cantilever fluctuation d at various values of the heating current I is shown in Fig. 4a, where fH + F is indicated as the dotted line. The intensity of the sharp peak Δ
increases monotonically with increasing I. The amplitude calculated by subtracting background from d at the frequency fH + F, Δd, is proportional to the heating power I2, as shown in the red
disks and the solid curve in Fig. 4b. Since the spin-wave current intensity is proportional to the heating power I2, the experimental result is consistent with the torque generation due to
the spin-wave SSE. Figure 4c shows the spectra of the cantilever oscillation at various external a.c. fields. The sharp peak was found to be suppressed at fields below 4.0 mT. In the field
range, magnetic domains are introduced around the root of the cantilever, according to micro-magnetic simulation27 (see Supplementary Note 3 for details). Since a domain wall scatters spin
waves9, the efficiency of the spin-wave transmission or the resultant torque should decrease in such a low field range, as shown in Fig. 4c. The change in the resonance frequency f0 with
increasing field strength is attributed to the ΔE effect28,29, which refers to the modulation of Young’s modulus via magnetostriction, and we tuned the excitation frequency, fH + F, to f0−10
Hz in the measurement.
Fig. 4Current and field dependence of cantilever fluctuation d. a Amplitude of the cantilever fluctuation d at various values of the heating current I. The excitation frequency, 22.800 kHz, is
shown by the dotted line in the figure. b Fluctuation amplitude of the cantilever at the excitation frequency as a function of the current amplitude I. The red disks represent the
experimental data. The gray solid curve, which is proportional to I2, is a curve fitted to the data. c Amplitude of the cantilever fluctuation d at various values of the a.c. field strength.
The current amplitude is 600 μA
Full size imageDiscussionThe microscopic mechanism of the angular momentum transfer is likely composed of spin-orbit interaction, dipole-dipole interaction, and/or spin-rotation interaction30,31,32,33, but we
phenomenologically assumed that the spin-wave angular momentum is totally transferred to the cantilever dynamics via the spin-wave relaxation, similar to the Einstein-de Haas effects and the
mechanical rotation due to damping of FMR. By considering the mechanical boundary conditions, we estimated the force as |Fz| ~ 10−15 N for the heating current I = 300 μA, which is
consistent with the minimum detectable force by the cantilever at room temperature, Fmin = 1.33 × 10−15 N (see Supplementary Note 4 for details). Thus, the longitudinal relaxation of the
spin wave converts spin-wave angular momentum into mechanical force on the cantilever with fp ~ 20 kHz4,5.
In magnets, spin-wave relaxation is sensitive to the magnetic shape anisotropy via the many-body scattering of magnons28, in our sample, the shape anisotropy in the thin cantilever arm is
stronger than that in the bulk joint part. The magnons created in the joint part are thus strongly dissipated in the arm part, exerting torque on the cantilever. The shape anisotropy can be
controlled in terms of shapes of a magnet, and one can design where a spin wave is created in a magnet and where it is converted to mechanical torque. Furthermore, the present mechanism can
generate mechanical torque ceaselessly, different from the conventional Einstein-de Haas effects. These advantages can be applied to make various micro machines which can be driven from a
distant place free from wiring, but using heat or microwaves.
MethodsSample fabricationThe YIG cantilever used in the present study was fabricated with a dual beam FIB/SEM system (Versa3D DualBeam; FEI company) from a 3-µm-thick YIG (111) film epitaxially grown on a
single-crystalline GGG substrate by a liquid-phase epitaxy method. First, we prepared the electrode pads by the electron-beam lithography. Next, we patterned a cantilever shape by focused
Ga+ ion beam milling. To avoid magnetic-field disturbance from the YIG layer which surrounds the cantilever21, the surrounding YIG layer was removed about 30 µm away from the cantilever.
Then, the Pt heater wire with the width of 0.4 µm was fabricated by the FIB deposition. The ends of the wire were connected to the electrode pads. Finally, the part under the cantilever was
milled away by using an obliquely incident Ga+ ion beam. In the control sample, the trench at the root of the cantilever was shaped by Ga+ ion beam milling after the process explained above.
The depth of the trench is greater than 5 µm, enough to cut the YIG layer. After the milling, the trench was filled with carbon by the FIB deposition.
Measurement setupIn the present study, we measured vertical displacement of the cantilever by means of dual-frequency a.c. measurements based on a heterodyne detection method. The displacement was measured
with a laser-Doppler interferometer (MSA-100-3D; Polytec, Inc.). During the measurements, an a.c. heat with the frequency fH and an a.c. magnetic field with the frequency F were applied to
exclude effects of thermal stress from the displacement. In the condition, the signal of the spin Seebeck mechanical force, which depends on both the a.c heat and the a.c field, appears at
the frequency of fH ± F, and any signals due to thermal stress, which are independent of the a.c. field, appear at the frequency of fH. Therefore, we can distinguish the spin Seebeck
mechanical force from other artifacts originated in thermal effects. By tuning the excitation frequency fH + F into the resonance band of the cantilever, the signal at fH + F is resonantly
amplified compared to off resonance bending. The signal at fH−F is out of range of the resonance band of the cantilever, and it is not detectable.
The a.c. heat was generated by applying an alternating current I with the frequency of fH/2 through the heater wire. The amplitude of I was controlled to be constant by using a V-I
converter. The field strength was monitored with a Hall probe (HGT-2010; Lakeshore, Inc.). To separate the signal from a background, we tuned the excitation frequency fH + F to be about 5 Hz
less than the centre frequency of the cantilever fluctuation. Note that, in the single-frequency measurement in which an a.c. heat and a d.c. magnetic field were applied, the obtained
signal does not depend on the field direction, which means that the signal of spin Seebeck mechanical force is completely hidden by thermal effects. All experiments were performed at room
temperature in a high vacuum (10−4 Pa).
Data availabilityThe data that support the findings of this study are available from the corresponding author on request.
References Einstein, A. & de Haas, W. J. Experimental proof of the existence of Ampère’s molecular currents. KNAW proc. 18 I, 696–711 (1915).
Google Scholar
Scott, G. G. Review of gyromagnetic ratio experiments. Rev. Mod. Phys. 34, 102–109 (1962).
Article ADS Google Scholar
Wallis, T. M., Moreland, J. & Kabos, P. Einstein-de Haas effect in a NiFe film deposited on a microcantilever. Appl. Phys. Lett. 89, 122502 (2006).
Article ADS Google Scholar
Jander, A., Moreland, J. & Kabos, P. Angular momentum and energy transferred through ferromagnetic resonance. Appl. Phys. Lett. 78, 2348–2350 (2001).
Article CAS ADS Google Scholar
Jander, A., Moreland, J. & Kabos, P. Micromechanical detectors for local field measurements based on ferromagnetic resonance. J. Appl. Phys. 89, 7086–7090 (2001).
Article CAS ADS Google Scholar
Stancil, D. D. & Prabhakar, A. Spin Waves (Springer, New York, 2009).
Kajiwara, Y. et al. Transmission of electrical signals by spin-wave interconversion in a magnetic insulator. Nature 464, 262–266 (2010).
Article CAS ADS Google Scholar
Cornelissen, L. J., Liu, J., Duine, R. A., Ben Youssef, J. & van Wees, B. J. Long-distance transport of magnon spin information in a magnetic insulator at room temperature. Nat. Phys. 11,
1022–1026 (2015).
Article CAS Google Scholar
Maekawa, S., Valenzuela, S. O., Saitoh, E. & Kimura, T. (eds) Spin Current; 2nd edn. (Oxford Univ. Press, Oxford, 2017).
Goennenwein, S. T. B., Maekawa, S. & Bauer, G. E. W. Spin mechanics. Solid State Commun. 198, 1–2 (2014).
Article CAS ADS Google Scholar
Uchida, K. et al. Observation of the spin Seebeck effect. Nature 455, 778–781 (2008).
Article CAS ADS Google Scholar
Uchida, K. et al. Spin Seebeck insulator. Nat. Mater. 9, 894–897 (2010).
Article CAS ADS Google Scholar
Uchida, K. et al. Observation of longitudinal spin-Seebeck effect in magnetic insulators. Appl. Phy. Lett. 97, 172505 (2010).
Article ADS Google Scholar
Uchida, K. et al. Thermoelectric generation based on spin Seebeck effects. Proc. IEEE. 104, 1946–1973 (2016).
Article CAS Google Scholar
Weiler, M. et al. Experimental test of the spin mixing interface conductivity concept. Phys. Rev. Lett. 111, 176601 (2013).
Article Google Scholar
Saitoh, E., Ueda, M., Miyajima, H. & Tatara, G. Conversion of spin current into charge current at room temperature: inverse spin-Hall effect. Appl. Phys. Lett. 88, 182509 (2006).
Article ADS Google Scholar
Zhang, S. S.-L. & Zhang, S.-F. Magnon mediated electric current drag across a ferromagnetic insulator layer. Phy. Rev. Lett. 109, 096603 (2012).
Article ADS Google Scholar
Rezende, S. M. et al. Magnon spin-current theory for the longitudinal spin-Seebeck effect. Phys. Rev. B 89, 014416 (2014).
Article ADS Google Scholar
Zolfagharkhani, G. et al. Nanomechanical detection of itinerant electron spin flip. Nat. Nanotech. 3, 720–723 (2008).
Article CAS ADS Google Scholar
Inomata, N., Toda, M., Sato, M., Ishijima, A. & Ono, T. Pico calorimeter for detection of heat produced in an individual brown fat cell. Appl. Phys. Lett. 100, 154104 (2012).
Article ADS Google Scholar
Ono, T., Li, X., Miyashita, H. & Esashi, M. Mass sensing of adsorbed molecules in sub-picogram sample with ultrathin silicon resonator. Rev. Sci. Instrum. 74, 1240–1243 (2003).
Article CAS ADS Google Scholar
Losby, J. E. et al. Torque-mixing magnetic resonance spectroscopy. Science 350, 798–801 (2015).
Article CAS ADS Google Scholar
Seo, Y. J. et al. Fabrication and magnetic control of Y3Fe5O12 cantilevers. Appl. Phys. Lett. 110, 132409 (2017).
Article ADS Google Scholar
Shan, J. et al. Influence of yttrium iron garnet thickness and heater opacity on the nonlocal transport of electrically and thermally excited magnons. Phys. Rev. B 94, 174437 (2016).
Article ADS Google Scholar
Padture, N. P. & Klemens, P. G. Low thermal conductivity in garnets. J. Am. Ceram. Soc. 80, 1018–1020 (1997).
Article CAS Google Scholar
Khizhnyak, P. E., Chechetkin, A. V. & Glybin, A. P. Thermal conductivity of carbon black. J. Eng. Phys. 37, 1073–1075 (1979).
Article Google Scholar
The Object Oriented MicroMagnetic Framework (OOMMF) project at ITL/NIST, https://math.nist.gov/oommf/
Jahns, R. et al. Microelectromechanical magnetic field sensor based on ΔE effect. Appl. Phys. Lett. 105, 052414 (2014).
Article ADS Google Scholar
Squire, P. T. Phenomenological model for magnetization, magnetostriction and ΔE effect in field-annealed amorphous ribbons. J. Magn. Magn. Mater. 87, 299–310 (1990).
Article ADS Google Scholar
Maekawa, S. & Tachiki, M. Surface acoustic attenuation due to surface spin wave in ferro- and antiferromagnets. AIP Conf. Proc. 29, 542–543 (1976).
Article CAS ADS Google Scholar
Gurevich, A. G. & Melkov, G. A. Magnetization Oscillations and Waves (CRC Press, Boca Raton, Florida, 1996).
Matsuo, M., Ieda, J., Saitoh, E. & Maekawa, S. Effects of mechanical rotation on spin currents. Phys. Rev. Lett. 106, 076601 (2011).
Article ADS Google Scholar
Chudo, H. et al. Observation of Barnett fields in solids by nuclear magnetic resonance. Appl. Phys. Express 7, 063004 (2014).
Article ADS Google Scholar
Download references
AcknowledgementsWe thank Dr. Y. Oikawa, Dr. T. Kikkawa, Dr. Z.-Y. Qiu, Dr. D.-Z. Hou, Dr. J. Ieda, Dr. M. Ono, Dr. M. Imai, Dr. S. Okayasu, and Dr Y. Ohnuma for valuable discussions. This work was supported
by JST-ERATO Spin Quantum Rectification Project (JPMJER1402) from JST, Japan; Grant-in-Aid for Scientific Research on Innovative Areas Nano Spin Conversion Science (26103005), Grant-in-Aid
for Scientific Research on Innovative Areas (18H04311, 18H04215), Grant-in-Aid for Scientific Research A (26247063), Grant-in-Aid for Scientific Research B (16H04023, 17H02927), Grant-in-Aid
for Scientific Research C (15K05153), and Grant-in-Aid for Young Scientists A (17H04806) from MEXT, Japan. K.O. acknowledges support from GP-Spin at Tohoku University.
Author informationAuthors and Affiliations Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, 319-1195, Japan
Kazuya Harii, Hiroyuki Chudo, Sadamichi Maekawa & Eiji Saitoh
Advanced Institute for Materials Research, Tohoku University, Sendai, 980-8577, Japan
Kazuya Harii, Yong-Jun Seo & Eiji Saitoh
RIKEN Center for Emergent Matter Science, Wako, 351-0198, Japan
Yasumasa Tsutsumi, Mamoru Matsuo, Yuki Shiomi & Sadamichi Maekawa
Institute for Materials Research, Tohoku University, Sendai, 980-8577, Japan
Koichi Oyanagi & Eiji Saitoh
Kavli Institute for Theoretical Sciences, University of Chinese Academy of Sciences, Beijing, 100190, People’s Republic of China
Mamoru Matsuo & Sadamichi Maekawa
Quantum-Phase Electronics Center, The University of Tokyo, Tokyo, 113-8656, Japan
Yuki Shiomi
Department of Applied Physics, The University of Tokyo, Tokyo, 113-8656, Japan
Yuki Shiomi & Eiji Saitoh
Department of Mechanical and Aerospace Engineering, Tohoku University, Sendai, 980-8579, Japan
Takahito Ono
AuthorsKazuya HariiView author publications You can also search for this author inPubMed Google Scholar
Yong-Jun SeoView author publications You can also search for this author inPubMed Google Scholar
Yasumasa TsutsumiView author publications You can also search for this author inPubMed Google Scholar
Hiroyuki ChudoView author publications You can also search for this author inPubMed Google Scholar
Koichi OyanagiView author publications You can also search for this author inPubMed Google Scholar
Mamoru MatsuoView author publications You can also search for this author inPubMed Google Scholar
Yuki ShiomiView author publications You can also search for this author inPubMed Google Scholar
Takahito OnoView author publications You can also search for this author inPubMed Google Scholar
Sadamichi MaekawaView author publications You can also search for this author inPubMed Google Scholar
Eiji SaitohView author publications You can also search for this author inPubMed Google Scholar
ContributionsK.H., Y-J.S., H.C., and Y.S. designed the experiments. K.H., Y-J.S., K.O., and Y.S. collected and analyzed the data. H.C. and T.O. supported the experiments. Y.T., M.M., and S.M developed
the theoretical explanation. E.S. planned and supervised the study. K.H., Y.T., H.C., and E.S. wrote the manuscript. K.H. and Y-J.S. contributed equally to this work. All authors discussed
the results and commented on the manuscript.
Corresponding author Correspondence to Kazuya Harii.
Ethics declarations Competing interestsThe authors declare no competing interests.
Additional informationJournal peer review information: Nature Communications thanks the anonymous reviewers for their contribution to the peer review of this work. Peer reviewer reports are available.
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary informationSupplementaryInformationPeer ReviewRights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or
format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or
other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in
the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the
copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and permissions
About this articleCite this article Harii, K., Seo, YJ., Tsutsumi, Y. et al. Spin Seebeck mechanical force. Nat Commun 10, 2616 (2019). https://doi.org/10.1038/s41467-019-10625-y
Download citation
Received: 08 November 2018
Accepted: 20 May 2019
Published: 13 June 2019
DOI: https://doi.org/10.1038/s41467-019-10625-y
Share this article Anyone you share the following link with will be able to read this content:
Get shareable link Sorry, a shareable link is not currently available for this article.
Copy to clipboard Provided by the Springer Nature SharedIt content-sharing initiative
This article is cited by Actuation of microstructures with spin-current volume effect Yi-Te HuangKenta SuzukiTakahito Ono Communications Engineering (2024)
Spin transport in a lateral spin valve with a suspended Cu channel Kenjiro MatsukiRyo OhshimaMasashi Shiraishi Scientific Reports (2020)
Large Magneto-piezoelectric Effect in EuMnBi2 Single Crystal at Low Temperatures Yuki ShiomiHidetoshi MasudaShintaro lshiwata Scientific Reports (2020)