Play all audios:
ABSTRACT Multidimensional sensing offers advantages in accuracy, diversity and capability for the simultaneous detection and discrimination of multiple analytes, however, the previous
reports usually require complicated synthesis/fabrication process and/or need a variety of techniques (or instruments) to acquire signals. Therefore, to take full advantages of this concept,
simple designs are highly desirable. Herein, a novel concept is conceived to construct multidimensional sensing platforms based on a single indicator that has capability of showing diverse
color/fluorescence responses with the addition of different analytes. Through extracting hidden information from these responses, such as red, green and blue (RGB) alterations, a
triple-channel-based multidimensional sensing platform could consequently be fabricated and the RGB alterations are further applicable to standard statistical methods. As a proof-of-concept
study, a triple-channel sensing platform is fabricated solely using dithizone with assistance of cetyltrimethylammonium bromide (CTAB) for hyperchromicity and sensitization, which
demonstrates superior capabilities in detection and identification of ten common heavy metal ions at their standard concentrations of wastewater-discharge of China. Moreover, this sensing
platform exhibits promising applications in semi-quantitative and even quantitative analysis individuals of these heavy metal ions with high sensitivity as well. Finally, density functional
theory calculations are performed to reveal the foundations for this analysis. SIMILAR CONTENT BEING VIEWED BY OTHERS SIMPLE DIHYDROPYRIDINE-BASED COLORIMETRIC CHEMOSENSORS FOR HEAVY METAL
ION DETECTION, BIOLOGICAL EVALUATION, MOLECULAR DOCKING, AND ADMET PROFILING Article Open access 18 September 2023 A MULTICOLOR AND RATIOMETRIC FLUORESCENT SENSING PLATFORM FOR METAL IONS
BASED ON ARENE–METAL-ION CONTACT Article Open access 06 July 2021 A NOVEL GALLIUM OXIDE NANOPARTICLES-BASED SENSOR FOR THE SIMULTANEOUS ELECTROCHEMICAL DETECTION OF PB2+, CD2+ AND HG2+ IONS
IN REAL WATER SAMPLES Article Open access 23 November 2022 INTRODUCTION Multidimensional sensing devices, which offer advantages in accuracy, diversity and capability for the simultaneous
detection and discrimination of multiple analytes, have received increasing attention in recent years1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24. Traditionally, three
strategies are often employed to construct multidimensional sensing systems: i) combining a variety of cross-reactively colorimetric or fluorometric indicators (i.e. sensor array
approach)1,2,3,4,5,6,7,8,9,10,11,12; ii) mechanically incorporating several, such as mass-sensitive, capacitive and calorimetric transducers onto a single chip (i.e. smart chip
approach)13,14,15; and iii) integrating fluorescent, phosphorescent, light-scattering, absorbing, and/or electrochemiluminescent (ECL) reporters on a molecule or a nanoparticle (i.e.
lab-on-a-molecule/nanoparticle approach)16,17,18,19,20,21,22,23,24. These efforts have made great progress toward developing multidimensional sensing systems, however, they either require
complicated synthesis/fabrication process and/or need a variety of techniques (or instruments) to acquire sensing signals, thus limiting their widespread applications. In order to take full
advantages of the concept of multidimensional sensing, more simple design strategies are highly desirable and have in fact emerged recently. For example, Ouyang _et al_. reported a visual
sensor array for recognition and analysis of proteins using two types of fluorescent gold nanoclusters25. Song _et al_. designed and fabricated microchips for recognition of metal ions based
on a single indicator _via_ multiple fluorescent channels26,27. Encouraged by these advances, we are interested in seeking even more simple but general strategies to construct
multidimensional sensing systems. Inspired by the knowledge that certain indicators show distinct color or fluorescent responses to different analytes25,26,27,28,29, in this current study, a
triple-channel-based multidimensional sensing platform is proposed to fabricate through extracting more hidden information, such as red, green and blue (RGB) alterations, from the color or
fluorescent responses of a single indicator. As a proof-of-concept study, dithizone was taken as an example of the single indicator. Through extracting RGB color alterations of dithizone
with the addition of diverse metal ions, a triple-channel based multidimensional sensing platform could in principle be fabricated. Importantly, much better sensing performances are achieved
with assistance by the addition of cetyltrimethylammonium bromide (CTAB), a surfactant that is known for hyperchromicity and sensitization to a probe. This sensing platform is found to be
excellent in the detection and identification of ten common heavy metal ions at their standard concentrations of wastewater-discharge of China. In addition, this sensor also shows great
potentials in semi-quantitative and even quantitative analysis each of these heavy metal ions with high sensitivity. The approach to multidimensional sensing systems is considered to be
maximally simplified, including no need complicated synthesis, fabrication and utilization of expensive instruments. The interactions between dithizone and heavy metal ions had solely been
investigated from experimental characterization30 or conjecture31. Herein, the experimental means and density functional theory (DFT) calculations are performed to clarify the nature of
interactions between dithizone and diverse metal ions. The accurate chelates of dithizone products and nine heavy metal ions are determined at B3LYP/6-31G* level. The corresponding frontier
molecular orbital energies (i.e. HOMOs and LUMOs) and electronic distributions of the optimized chelates are also determined. More importantly, the calculated HOMO-LUMO gaps are found in
good agreement with the experimental data, confirming the reliability of the optimized configurations. The combination of experimental characterizations and theoretical calculations
demonstrate that the distinct color responses of the probe to metal ions result from the different interactions, electron distributions and transitions. RESULTS It’s known that certain
indicators show distinct color or fluorescence responses to different analytes25,26,27,28,29. For example, the dithizone and CTAB co-modified gold nanoparticles had been found to respond ten
types of heavy metal ions with different colors in our previous study29. Based on this knowledge, a triple-channel-based multidimensional sensing platform could be attempted to fabricate
through simply extracting red, green and blue (RGB) alterations from the indicator’s color responses with the addition of diverse analytes, as shown in Fig. 1. These RGB alterations are also
applicable to standard statistical methods (e.g. Hierarchical clustering analysis (HCA) and principal component analysis (PCA)) for further evaluating the capability of such a sensing
platform in detection and discrimination of multiple analytes. To do a proof-of-concept study, dithizone was taken as an example in this study, which had been reported showing different
color responses to diverse metal ions32,33. Given requirements of the practical application, ten common heavy metal ions (i.e. Hg2+, Cd2+, Pb2+, Cr(VI), Co2+, Ni2+, Cu2+, Zn2+, Mn2+ and Ag+)
at their standard concentrations of wastewater-discharge of China (Supplementary Information (SI) Table S1) are evaluated34. As shown in Fig. S1 (SI), dithizone does show different color
responses to six of the selected ten heavy metal ions (i.e. Co2+, Ni2+, Cu2+, Zn2+, Mn2+ and Ag+), but not to four of them (i.e. Hg2+, Cd2+, Cr(VI) and Pb2+), might be due to their
relatively low concentrations of wastewater-discharge standard. Through extracting the RGB alterations from these color responses, a triple-channel sensing platform is fabricated, which
clearly shows different recognition patterns for those six metal ions that can produce color changes to dithizone (Fig. S2 in SI). Moreover, when these RGB alterations are subjected to
standard statistical analysis (e.g. HCA and PCA), similar results as those triple-channel recognition patterns are observed (Fig. S3 in SI). Although the above results verified our concept,
the relatively poor detection performance may restrict its practical applications. However, keeping in mind that the sensitivity of a probe might be significantly improved with the presence
of surfactants (i.e. well-known sensitization effects of surfactants)35,36,37,38,39 and a cationic surfactant CTAB was attempted to sensitize dithizone’s response to metal ions. It’s
astonishing to us that much stronger responses of dithizone to the ten heavy metal ions are observed with the addition of CTAB. The sensitization effects of CTAB here probably can be
ascribed to its solubilization capacity to dithizone in aqueous solution and meanwhile forming a microenvironment that favouring interaction between metal ions and the probe35,36,37,38,39.
To obtain better sensing performances to metal ions with the dithizone and CTAB ensemble, further optimized experiments are performed. First of all, 30 μM of dithizone was selected and fixed
(for observing a clearly colored solution) and different ratios of CTAB to dithizone were examined. As seen in Fig. S4 (SI), the color responses (described by the total Euclidean distances,
EDs, _i.e_. square root of the sums of the squares of the ΔRGB values) of the mixture to 5 μM Cd2+ are found to be increased and reach a maximum at the ratio of 3:1 (CTAB to dithizone) and
then drop down at higher ratios. Secondly, pH influences on the color responses of the dithizone and CTAB mixture to metal ions were investigated. Experimental results exhibited that higher
pH conditions (e.g. pH > 7) are in favour of the recognition of metal ions, but precipitations tend to appear due to the formation of metal hydroxides if pH > 8. Hence, a 90 μM CTAB
and 30 μM dithizone mixture in pH 7.4 buffer is used as the optimal condition for the detection of metal ions in the following study. The color responses of the single indicator (i.e.
dithizone, 30 μM) in the presence of CTAB (90 μM) to the ten common heavy metal ions at their wastewater-discharge standard concentrations of China are investigated. For further reducing the
instrumental requiements, an ordinary flatbed scanner (or even a digital camera) is used to acquire digital images. As shown in Fig. 2a, from the color profiles of the dithizone-CTAB
mixture in the absence (named “before” images) and presence (named “after” images) of metal ions, distinctive color changes are observed to each of the ten heavy metal ions, even by naked
eye. For quantitative comparisons of these color changes, a difference map can be acquired by taking the difference of the RGB values from the “before” and “after” images. Through
exctracting the RGB alterations of the dithizone and CTAB mixture after addition of metal ions (the full data set are summarized in Table S2 of SI), a triple-channel sensing platform could
thus be constructed. To probe reproducibility of the sensing system and further statistical analysis, sextuple data are acquired. As shown in Fig. 2b, the ten heavy metal ions exhibit
distinct ΔRGB recognition patterns (can also be called fingerprints) at their wastewater-discharge standard concentrations with good reproducibility, which demonstrates the excellent
detection and discrimination capability of this sensing system. The multiple dispersion of this colorimetric sensor data requires a classification algorithm that uses the full dimensionality
of the data. Herein, HCA, which is a model-free method based on the grouping of the analyte vectors according to their spatial distances in their full vector space is employed40,41. On the
basis of the clustering of the sensor response data in the three-dimensional ΔRGB color space (Table S2 in SI), dendrograms formed by HCA are depicted in Fig. 2c. Remarkably, all the ten
heavy metal ions and a control are accurately classified with no errors out of 66 cases. This three-dimensional response patterns are also explored by PCA, which is a statistical treatment
used to reduce multidimensional data for easier interpretation42. The resulting two-dimensional PCA score plot (Fig. S5 in SI) shows clear clustering of the data using only the first two
principal components (representing 91.5% of the total variance), with excellent discriminatory capacity. The large distance between clusters in the PCA score plot reflects significantly
differential responses of the sensing system to heavy metal ions at their wastewater-discharge standard concentrations. To further explore capabilities of this sensing platform, such as
responses at other concentrations rather than wastewater-discharge standards, potentially quantitative analysis and limit of detection (LOD), the color responses of dithizone-CTAB mixture
with the addition of an individual metal ion at various concentrations are examined (Hg2+ and Cd2+ are taken as examples). As shown in Fig. 3a, more and more intense color responses are
observed with increasing concentrations of the two metal ions up to about 10 μM and these color changes can further be quantitatively indicated with total EDs (Fig. 3b,c). Importantly, nice
linear fitting curves are obtained with excellent correlations (R2 = 0.999) between the total EDs and the concentrations of the two representative heavy metal ions from 1 to 10 μM, which
actually provide possibilities for quantitative analysis. By means of extrapolating these fitting curves, the LODs are estimated to be 0.13 μM and 0.14 μM for Hg2+ and Cd2+, respectively
(see Table S3 in SI for fitting parameters), both being well lower than their concentrations of wastewater-discharge standard of China. Interestingly, PCA further demonstrates that the
dithizone-CTAB solution can be applied for not only effective identification and discrimination between Hg2+ and Cd2+, but their different concentrations (Fig. 3d). Furthermore, it’s worthy
to note herein, the comparisons of the color responses of dithizone to Cd2+ and Hg2+ in the absence and presence of CTAB clearly show that the sensitivities of dithizone are significantly
enhanced with the addition of CTAB (Fig. 3b,c). Therefore, the as-developed single-indicator-based sensing platform demonstrates not only great potentials in detection and differentiation of
multiple metal ions, but semi-quantitative and even quantitative analysis of individuals with high sensitivity, based on the corresponding color response profiles, RGB recognition patterns,
HCA/PCA and EDs fitting curves. To reveal the nature of distinct color responses of dithizone to diverse metal ions, of which lay the foundation for constructing the as-proposed
triple-channel multidimensional sensing platform, we extend our efforts to apply the experimental means and density functional theory (DFT) calculations to study the interactions between the
probe and heavy metal ions. Experimentally, the UV-vis absorption at the maximal wavelength (λmax) is mainly attributed to the electron transitions of HOMO to LUMO43,44,45,46. As shown in
Fig. S6 (SI), discinct UV-vis spectra are observed with the addition of different metal ions and the corresponding HOMO-LUMO energy gaps are calculated (see Table 1). But it’s hard to
achieve useful differentiation information solely from these spectra. Nevertheless, the HOMO-LUMO energy gaps of the sensing system with each of these heavy metal ions could be calculated.
Theoretically, DFT has been proven to be a powerful tool for determining the molecular structures and molecular orbitals45,46,47,48,49,50,51,52. Therefore, DFT calculations are applied to
determine the chelate structures of the probe to heavy metal ions and further for the corresponding HOMO to LUMO energy states. Based on the fact that dithizone decomposes to [SCH2N4]2− in
alkaline solution29, the chelates of [SCH2N4]2− to nine heavy metal ions (expect Cr(VI)) are actually performed. Note that the special structure of Cr(VI) (i.e. Cr2O72−) would produce
completely different structures with the probe from the other nine metal ions and therefore, Cr(VI) will not be discussed below. Through extensive DFT calculations using the optimized trial
structures at B3LYP/6-31G* level, we obtained the accurate chelates of SCH2N4M (M = Ni, Mn, Co, Cu, Zn, Pb, Hg, Cd and Ag) (Fig. 4). The shorter average distances of M-NH and M-N for Ni, Mn,
Co, Cu and Zn than that of Pb, Hg, Cd and Ag reveal their stronger coordination capabilities with [SCH2N4]2−. The Cartesian coordinates of the optimized structures are summarized in Table
S4 (SI). Moreover, for the purpose of clarifying the significant differences in the electronic distribution and transitions among the optimized chelates, their molecular orbitals have been
theoretically investigated on the basis of DFT calculations with B3LYP/6-31G* level as well. As shown in Fig. 4, the corresponding frontier molecular orbital energies (i.e. HOMOs and LUMOs)
and electronic distributions of the optimized chelates are found to be distinctively different. Their HOMO-LUMO gaps and the frontier molecular orbital energies are presented in Table 1 and
Fig. S7 (SI). The calculated HOMO-LUMO gap increases in the order from 2.0 eV for SCH2N4Cd, 2.10 eV for SCH2N4Co, 2.29 eV for SCH2N4Zn, 2.30 eV for SCH2N4Pb, 2.37 eV for SCH2N4Cu, 2.42 eV
for SCH2N4Mn, 2.50 eV for SCH2N4Hg, 2.58 eV for SCH2N4Ag, to 2.72 eV for SCH2N4Ni. Importantly, these calculated HOMO-LUMO gaps are found in high agreement with the experimental data (Table
1), which confirms the assumed chelating structures of the probe to metal ions. The combination of experimental characterizations and theoretical calculations demonstrate that the distinct
color changes of the probe to heavy metal ions result from the different interactions, electron distributions and transitions. The practical applicability of the as-developed sensing
platform is preliminarily evaluated using real wastewater samples (taken from Yongjiang River in Ningbo, China). Firstly, the real water sample was spiked with the ten heavy metal ions at
their standard concentrations of wastewater-discharge and then subject to the same analysis process as that of in deionized water. As shown in Fig. S8 (SI), clearly distinct color response
profiles of the sensor to each of the ten metal ions are observed, even by the naked eye. Similarly, the sextuple data are acquired to probe reproducibility of the sensing system and further
for statistical analysis. Again, the as-developed triple-channel sensing platform exhibits distinct ΔRGB recognition patterns to the ten heavy metal ions and are well separated from each
other based on PCA and HCA (Fig. S9 in SI). These findings demonstrate that the single-indicator-based triple-channel sensing platform can potentially be applied in analysis of real
wastewater samples. DISCUSSION In summary, a novel concept to fabricate multidimensional sensing platforms is proposed through simply extracting more hiddern information, such as RGB
alterations, from a single indicator that could show distinct color or fluorescence responses to diverse substances. As a proof-of-concept study, a triple-channel multi-ion analysis platform
is developed solely using dithizone with assistance of a surfactant (i.e. CTAB) for hyperchromicity and sensitization. Through extracting the RGB alterations of dithizone and CTAB mixture
to ten common heavy metal ions at their concentrations of wastewater-discharge of China, different recognition patterns (fingerprints) can be observed and HCA/PCA further demonstrate its
detection and discrimination capability. Moreover, this as-developed single-indicator-based sensing platform could as well as be applied in semiquantitative and even quantitative analysis of
a specific metal ions with high sensitivity based on their corresponding color response profiles and EDs fitting curves, respectively. To reveal the nature of distinct color responses of
dithizone to metal ions, DFT calculations are employed to determine their chelate structures and the corresponding HOMO-LUMO energy gaps. The high agreement of experimental characterizations
and theoretical calculations demonstrate that the optimized chelates are credible and the distinct color changes of the probe to heavy metal ions result from the different interactions,
electron distributions and transitions. Compared to the traditional strategies for multidimensional sensing systems, the greatest advantage of the as-proposed approach is considered to be
maximally simiplify the fabrication process. Notably, this work is only regarded as a preliminary step for exploration and application of the suggested single-indicator-based
multidimensional sensing concept and we are now focusing on extending its applications. The more recent research found that multiple proteins could also be detected and discriminated through
applying a single Au nanoparticles-based probe, demonstrating great potentials of general applicability of the as-proposed concept and the relevant results will be published separately
elsewhere later. METHODS MATERIALS AND INSTRUMENTS Dithizone, cetyltrimethylammonium bromide (CTAB) and K2Cr2O7 were from Sinopharm Chemical Reagent Co., Ltd (Beijing, China).
Mn(ClO4)2·6H2O, Ni(ClO4)2·6H2O, Cd(ClO4)2·6H2O, Hg(ClO4)2·3H2O and Zn(ClO4)2·6H2O were obtained from Strem Chemicals Inc. (Newburyport, USA). Pb(ClO4)2·3H2O and Co(ClO4)2·6H2O were purchased
from Sigma-Aldrich Co. (USA). AgNO3 and 4-(2-hydroxyethyl)piperazine-1-ethanesulfonic acid (HEPES) were from Aladdin Reagent Co. Ltd (Shanghai, China). Cu(ClO4)2·6H2O was purchased from
J&K Chemical Ltd. All chemicals were used as received without further purification. 96-well plates (Corning 3632) were obtained from Genetimes Technology. The stock solutions of metal
ions were prepared using 50 mM HEPES (pH 7.4) buffer. The pH measurements were performed using a PHS-3C pH meter. For all sensing experiments, imagings were acquired with a flatbed scanner
(Epson Perfection V300) in 96-well plates. UV-vis absorption spectra were recorded using a Lambda 950 UV-vis spectrophotometer from Perkin Elmer. Fourier transform infra-red (FT-IR)
spectroscopy was performed using a Nicolet 6700 spectrometer. METHOD FOR METAL IONS DETECTION AND DISCRIMINATION 1.0 mL of dithizone solution (1.0 mM in 0.2 M NaOH) was firstly mixed with 24
mL of CTAB solution (0.125 mM in H2O) and then mixed with HEPES buffer that in the absence (control solutions) or in the presence of certain concentrations of metal ions (work solutions) at
a volume ratio of 3:1. The final concentrations of dithizone, CTAB and HEPES are 30 μM, 90 μM and 10 mM, respectively. 300 μL of the control and work solutions were loaded into a 96-well
plate, respectively and the “before” (from the control solutions) and “after” (from the work solutions) images were acquired on an Epson Perfection V300 photo flatbed scanner. Difference
maps were acquired by taking the difference of the RGB values from the center of the indicator solution (in 96-well plates) from the “before” and “after” images using the commercial
Photoshop software. The chemometric analysis was performed on the color difference vectors using the Multi-Variate Statistical Package (MVSP v.3.1, Kovach Computing); in all cases,
hierarchical cluster analysis (HCA) and principal component analysis (PCA) were performed on the database library (Table S2) using the minimum variance for classification. ANALYSIS OF METAL
IONS IN REAL SAMPLES Metal ions detection in wastewater from Yongjiang River (located in Ningbo, China) was taken as an example to preliminarily test the capability of the as-developed
sensing platform for real samples. The analysis procedure was the same as the above description, just by using wastewater from Yongjiang River instead of deionized water. CALCULATIONS The
geometry optimizations of dithizone, dithizone products and the chelate structures of dithizone product and heavy metal ions, their molecular orbitals were performed by means of DFT methods
using the Gaussian03 quantum chemistry package at the B3LYP/6-31G* level. ADDITIONAL INFORMATION HOW TO CITE THIS ARTICLE: Leng, Y. _et al_. Single-indicator-based Multidimensional Sensing:
Detection and Identification of Heavy Metal Ions and Understanding the Foundations from Experiment to Simulation. _Sci. Rep_. 6, 25354; doi: 10.1038/srep25354 (2016). REFERENCES * Rakow, N.
A. & Suslick, K. S. A colorimetric sensor array for odour visualization. Nature 406, 710–713 (2000). Article ADS CAS PubMed Google Scholar * Askim, J. R., Mahmoudi, M. &
Suslick, K. S. Optical sensor arrays for chemical sensing: the optoelectronic nose. Chem. Soc. Rev. 42, 8649–8682 (2013). CAS PubMed Google Scholar * Diehl, K. L. & Anslyn, E. V.
Array sensing using optical methods for detection of chemical and biological hazards. Chem. Soc. Rev. 42, 8596–8611 (2013). CAS PubMed Google Scholar * Anzenbacher, P. Jr., Lubal, P.,
Buček, P., Palaciosa, M. A. & Kozelkovaa, M. E. A practical approach to optical cross-reactive sensor arrays. Chem. Soc. Rev. 39, 3954–3979 (2010). CAS PubMed Google Scholar * Albert,
K. J. et al. Cross-reactive chemical sensor arrays. Chem. Rev. 100, 2595–2626 (2000). CAS PubMed Google Scholar * Kreno, L. E. et al. Metal–organic framework materials as chemical
sensors. Chem. Rev. 112, 1105–1125 (2012). CAS PubMed Google Scholar * Qian, S. H. & Lin, H. W. Colorimetric sensor array for detection and identification of organophosphorus and
carbamate pesticides. Anal. Chem. 87, 5395–5400 (2015). CAS PubMed Google Scholar * Liu, L. & Lin, H. W. Paper-based colorimetric array test strip for selective and semiquantitative
multi-ion analysis: simultaneous detection of Hg2+, Ag+ and Cu2+. Anal. Chem. 86, 8829–8834 (2014). CAS PubMed Google Scholar * Selvakumar, K., Motiei, L. & Margulies, D.
Enzyme–artificial enzyme interactions as a means for discriminating among structurally similar isozymes. J. Am. Chem. Soc. 137, 4892–4895 (2015). CAS PubMed Google Scholar * Liu, Y. &
Bonizzoni, M. A supramolecular sensing array for qualitative and quantitative analysis of organophosphates in water. J. Am. Chem. Soc. 136, 14223–14229 (2014). CAS PubMed Google Scholar
* Greñu, B. D. D. et al. Fluorescent discrimination between traces of chemical warfare agents and their mimics. J. Am. Chem. Soc. 136, 4125–4128 (2014). Google Scholar * Zhang, Z. et al.
Expanded porphyrin-anion supramolecular assemblies: environmentally responsive sensors for organic solvents and anions. J. Am. Chem. Soc. 137, 7769–7774 (2015). CAS PubMed Google Scholar
* Hagleitner, C. et al. Smart single-chip gas sensor microsystem. Nature 414, 293–296 (2001). ADS CAS PubMed Google Scholar * Hierlemann, A. & Gutierrez-Osuna, R. Higher-order
chemical sensing. Chem. Rev. 108, 563–613 (2008). CAS PubMed Google Scholar * Kwon, O. S. et al. Multidimensional conducting polymer nanotubes for ultrasensitive chemical nerve agent
sensing. Nano Lett. 12, 2797–2802 (2012). ADS CAS PubMed Google Scholar * Chen, K., Shu, Q. & Schmittel, M. Design strategies for lab-on-a-molecule probes and orthogonal sensing.
Chem. Soc. Rev. 44, 136–160 (2015). CAS PubMed Google Scholar * Schmittel, M. & Lin, H.-W. Quadruple-channel sensing: a molecular sensor with a single type of receptor site for
selective and quantitative multi-ion analysis. Angew. Chem. Int. Ed. 46, 893–896 (2007). CAS Google Scholar * Ling, Y., Gao, Z. F., Zhou, Q., Li, N. B. & Luo, H. Q. Multidimensional
optical sensing platform for detection of heparin and reversible molecular logic gate operation based on the phloxine B/polyethyleneimine system. Anal. Chem. 87, 1575–1581 (2015). CAS
PubMed Google Scholar * Wu, P., Miao, L.-N., Wang, H.-F., Shao, X.-G. & Yan, X.-P. A multidimensional sensing device for the discrimination of proteins based on manganese-doped ZnS
quantum dots. Angew. Chem. Int. Ed. 50, 8118–8121 (2011). CAS Google Scholar * Lee, J. S., Shin, D. H., Jun, J. & Jang, J. Multidimensional polypyrrole/iron oxyhydroxide hybrid
nanoparticles for chemical nerve gas agent sensing application. ACS Nano 7, 10139–10147 (2013). CAS PubMed Google Scholar * Bajaj, A. et al. Detection and differentiation of normal,
cancerous and metastatic cells using nanoparticle-polymer sensor arrays. Proc. Nat. Acad. Sci. USA 106, 10912–10916 (2009). ADS CAS PubMed Google Scholar * Magri, D. C., Fava, M. C.
& Mallia, C. J. A sodium-enabled ‘pourbaix sensor’: a three-input AND logic gate as a ‘lab-on-a-molecule’ for monitoring Na+, pH and pE. Chem. Commun. 50, 1009–1011 (2014). CAS Google
Scholar * Lu, Y., Kong, H., Wen, F., Zhang, S. & Zhang, X. Lab-on-graphene: graphene oxide as a triple-channel sensing device for protein discrimination. Chem. Commun. 49, 81–83 (2013).
CAS Google Scholar * Sang L. J. & Wang, H. F. Aminophenylboronic-acid-conjugated polyacrylic acid Mn-doped ZnS quantum dot for highly sensitive discrimination of glycoproteins. Anal.
Chem. 86, 5706–5712 (2014). CAS PubMed Google Scholar * Xu, S. et al. A visual sensor array for pattern recognition analysis of proteins using novel blue-emitting fluorescent Gold
nanoclusters. Anal Chem. 86, 11634–11639 (2014). CAS PubMed Google Scholar * Huang,Y., Li, F., Qin, M., Jiang, L. & Song, Y. A multi-stopband photonic-crystal microchip for
high-performance metal-ion recognition based on fluorescent detection. Angew. Chem. Int. Ed. 52, 7296–7299 (2013). CAS Google Scholar * Huang, Y. et al. A photochromic sensor microchip for
high-performance multiplex metal ions detection. Sci. Rep. 5, 9724 (2015). CAS PubMed PubMed Central Google Scholar * Pan, L. et al. Truly fluorescent excitation-dependent carbon dots
and their applications in multicolor cellular imaging and multidimensional sensing. Adv. Mater. 27, 7782–7787 (2015). CAS PubMed Google Scholar * Leng, Y. et al. Colorimetric response of
dithizone product and hexadecyl trimethyl ammonium bromide modified gold nanoparticle dispersion to 10 types of heavy metal ions: understanding the involved molecules from experiment to
simulation. Langmuir 29, 7591–7599 (2013). CAS PubMed Google Scholar * Ly, N. H. & Joo, S. Zn(II)-concentration dependent Raman spectra in the dithizone complex on gold nanoparticle
surfaces in environmental water samples. Appl. Surf. Sci. 356, 1005–1011 (2015). ADS CAS Google Scholar * Sedghi, R., Heidari, B. & Behbahani, M. J. Synthesis, characterization and
application of poly(acrylamide-co-methylenbisacrylamide) nanocomposite as a colorimetric chemosensor for visual detection of trace levels of Hg and Pb ions. J. Hazard Mater. 285, 109–116
(2015). CAS PubMed Google Scholar * White, W. E. Dithizone as an analytical reagent. J. Chem. Edu. 13, 369–373 (1936). CAS Google Scholar * Wichmann, H. J. Isolation and detemination of
traces of metals. Ind. Eng. Chem. Anal. Ed. 11, 66–72 (1939). CAS Google Scholar * _Integrated wastewater discharge standard_. _Chinese national standards_. (GB8978-1996) Available at:
http://english.mep.gov.cn/standards_reports/standards/water_environment/Discharge_standard/200710/t20071024_111803.htm. (Accessed: 18th March 2016). * Pedro, J. A. et al. Surface charge of
zwitterionic sulfobetaine micelles with 2-naphthol as a fluorescent probe. Langmuir 28, 17623–17631 (2012). CAS PubMed Google Scholar * Kumari, N., Dey, N., Jha, S. & Bhattacharya, S.
Ratiometric, reversible and parts per billion level detection of multiple toxic transition metal ions using a single probe in micellar media. ACS Appl. Mater. Interfaces 5, 2438–2445
(2013). CAS PubMed Google Scholar * Priebe, J. P. et al. The chameleon-like nature of zwitterionic micelles: effect of cation binding. Langmuir 28, 1758–1764 (2012). CAS PubMed Google
Scholar * Fiedler, H. D. et al. Cd(II) determination in the presence of aqueous micellar solutions. Talanta 64, 190–195 (2004). CAS PubMed Google Scholar * Nasr, A. T., Alexander, K.,
Schreiner, L. J. & McAuley, K. B. Leuco-crystal-violet micelle gel dosimeters: I. influence of recipe components and potential sensitizers. Phys. Med. Biol. 60, 4665–4683 (2015). CAS
PubMed Google Scholar * Haswell, S. J. Practical Guide to Chemometrics, (New York, 1992). * Johnson, R. A. & Wichern, D. W. Applied Multivariate Statistical Analysis, 6th ed.,
(Prentice Hall: Upper Saddle River, NJ, 2007). * Jolliffe, I. T. Principal Component Analysis, (New York, 2002). * Shiraishi,Y., Matsunaga, Y. & Hirai, T. Selective colorimetric sensing
of Co(II) in aqueous media with a spiropyran–amide–dipicolylamine linkage under UV irradiation. Chem. Commun. 48, 5485–5487 (2012). CAS Google Scholar * Zhang, P., Tang, B., Tian, W.,
Yang, B. & Li, M. The comparative investigation on the optical properties and electronic structures of the alkoxy-tuned 1,3,4-oxadiazole derivatives. Mater. Chem. Phys. 119, 243–248
(2010). CAS Google Scholar * Qi, D., Zhang, L., Zhang, Y., Bian, Y. & Jiang, J. Nature of the intense near-IR absorption and unusual broad UV-visible-NIR spectra of azulenocyanines:
density functional theory studies. J. Phys. Chem. A 114, 13411–13417 (2010). CAS PubMed Google Scholar * Kityk, A. V. Absorption and fluorescence spectra of heterocyclic isomers from
long-range-corrected density functional theory in polarizable continuum approach. J. Phys. Chem. A 116, 3048–3055 (2012). CAS PubMed Google Scholar * Leng, Y. et al. A rapid and sensitive
colorimetric assay method for Co2+ based on the modified Au nanoparticles (NPs): understanding the involved interactions from experiments and simulations. Talanta 94, 271–277 (2012). CAS
PubMed Google Scholar * Leng, Y., Zhang, M., Song, C., Chen, M. & Lin, Z. A semi-empirical and Ab Initio combined approach for the full conformational searches of gaseous lysine and
lysine-H2O complex. J. Mol. Struct. (THEOCHEM) 858, 52–65 (2008). CAS Google Scholar * Peña, I., Sanz, M. E., López, J. C. & Alonso, J. L. Preferred conformers of proteinogenic
glutamic acid. J. Am. Chem. Soc. 134, 2305–2312 (2012). PubMed Google Scholar * Baggett, A. W., Guo, F., Li. B., Liu, S. & Jäkle, F. Regioregular synthesis of azaborine oligomers and a
polymer with a _syn_ conformation stabilized by N—H…π interactions. Angew. Chem. Int. Ed. 54, 11191–11195 (2015). CAS Google Scholar * Alonso, J. L. et al. The conformational behaviour of
free D-glucose—at last. Chem Sci. 5, 515–522 (2014). CAS Google Scholar * Peña, I., Cabezas, C. & Alonso, J. L. The nucleoside uridine isolated in the gas phase. Angew. Chem. Int. Ed.
127, 3034–3037 (2015). Google Scholar Download references ACKNOWLEDGEMENTS This work is supported by the Natural Science Foundation of China (21277149 and 51374132), Zhejiang Provincial
Natural Science Foundation of China (LR13B050001) and the Ningbo Science and Technology Bureau (2014B82010). Y.L. would also like to thank the financial support from the Science and
Technology Program of Education Department of Henan Province (14A430024), Natural Science Foundation of Nanyang Normal University (zx2014087) and China Postdoctoral Science Foundation
(2015M581970). Z.L. would also like to thank the financial support from Technicians Troop Construction Projects of Henan Province (No. C20150029). AUTHOR INFORMATION AUTHORS AND AFFILIATIONS
* Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, Ningbo, 315201, China Yumin Leng, Sihua Qian, Yuhui Wang & Hengwei Lin * College of
Physics and Electronic Engineering, Nanyang Normal University, Nanyang, 473061, China Yumin Leng, Cheng Lu, Xiaoxu Ji & Zhiwen Lu Authors * Yumin Leng View author publications You can
also search for this author inPubMed Google Scholar * Sihua Qian View author publications You can also search for this author inPubMed Google Scholar * Yuhui Wang View author publications
You can also search for this author inPubMed Google Scholar * Cheng Lu View author publications You can also search for this author inPubMed Google Scholar * Xiaoxu Ji View author
publications You can also search for this author inPubMed Google Scholar * Zhiwen Lu View author publications You can also search for this author inPubMed Google Scholar * Hengwei Lin View
author publications You can also search for this author inPubMed Google Scholar CONTRIBUTIONS Y.L. performed the experiments, calculations and drafted the manuscript. Y.L., S.Q., Y.W., C.L.,
X.J. and Z.L. analysed the data. Y.W. and H.L. conceived the idea, designed the experiments and wrote the paper. ETHICS DECLARATIONS COMPETING INTERESTS The authors declare no competing
financial interests. ELECTRONIC SUPPLEMENTARY MATERIAL SUPPLEMENTARY INFORMATION RIGHTS AND PERMISSIONS This work is licensed under a Creative Commons Attribution 4.0 International License.
The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not
included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit
http://creativecommons.org/licenses/by/4.0/ Reprints and permissions ABOUT THIS ARTICLE CITE THIS ARTICLE Leng, Y., Qian, S., Wang, Y. _et al._ Single-indicator-based Multidimensional
Sensing: Detection and Identification of Heavy Metal Ions and Understanding the Foundations from Experiment to Simulation. _Sci Rep_ 6, 25354 (2016). https://doi.org/10.1038/srep25354
Download citation * Received: 10 February 2016 * Accepted: 11 April 2016 * Published: 05 May 2016 * DOI: https://doi.org/10.1038/srep25354 SHARE THIS ARTICLE Anyone you share the following
link with will be able to read this content: Get shareable link Sorry, a shareable link is not currently available for this article. Copy to clipboard Provided by the Springer Nature
SharedIt content-sharing initiative