Photon-noise-limited cold-electron bolometer based on strong electron self-cooling for high-performance cosmology missions

Photon-noise-limited cold-electron bolometer based on strong electron self-cooling for high-performance cosmology missions

Play all audios:

Loading...

ABSTRACT Bolometers for balloon and space missions have seen extensive development because of their capacity to test primordial conditions of the Universe. The major improvements consist in


lowering the operating temperature to reach higher sensitivities. Here we show that an array of 192 cold-electron bolometers (CEB) demonstrates photon-noise-limited operation at the cryostat


temperature of 310 mK due to effective self-cooling of the absorber. The direct electron cooling of nanoabsorber placed between normal metal - insulator - superconductor junctions has


considerably higher efficiency than indirect cooling through massive suspended platform, that requires overcoming a weak electron-phonon conductance. The electron temperature reached 120 mK


without a power load, and 225 mK with a 60 pW power load with self-noise of a single bolometer below \(3\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) at a 0.01 pW power load. This


bolometer works at electron temperature less than phonon temperature, thus being a good candidate for future space missions without the use of dilution refrigerators. SIMILAR CONTENT BEING


VIEWED BY OTHERS RECORD ELECTRON SELF-COOLING IN COLD-ELECTRON BOLOMETERS WITH A HYBRID SUPERCONDUCTOR-FERROMAGNETIC NANOABSORBER AND TRAPS Article Open access 15 December 2020 BOLOMETER


OPERATING AT THE THRESHOLD FOR CIRCUIT QUANTUM ELECTRODYNAMICS Article 30 September 2020 UNCOOLED SUB-GHZ SPIN BOLOMETER DRIVEN BY AUTO-OSCILLATION Article Open access 26 January 2021


INTRODUCTION Bolometers for astrophysical applications and especially for balloon and space missions are under intense development thanks to challenging, new tasks such as measurement of the


primordial B-mode polarization left after the inflation stage of the evolution of the universe1,2. The trend in bolometer development is such that sensitivity, defined as the noise


equivalent power (NEP), is increased by lowering the operating temperature of the bolometer. This is true for both types of the most commonly developed bolometers: the transition edge sensor


(TES)3,4,5 and the kinetic inductance detector (KID)6. We have developed a cold-electron bolometer (CEB)7,8,9,10 with a normal metal absorber whose working body is the electron gas. The


maximal responsivity in current-bias mode8 at temperatures \({k}_{{\rm{B}}}{T}_{{\rm{e}}}\ll\Delta\) and voltages \({k}_{{\rm{B}}}{T}_{{\rm{e}}}< \ \Delta -{k}_{{\rm{B}}}{T}_{{\rm{e}}}\)


depends on the temperature \({T}_{e}\) of the electron gas as $${S}_{{\rm{V}}}^{{\mathrm{max}}}=1-2\frac{{k}_{{\rm{B}}}}{e\Sigma {V}_{{\rm{N}}}{T}_{{\rm{e}}}^{4}}.$$ (1) where


\({k}_{{\rm{B}}}\) is the Boltzmann constant, \(e\) is the electron charge, \(\Sigma\) is the experimentally determined electron–phonon coupling constant11 and \({V}_{{\rm{N}}}\) is the


volume of the normal absorber. As one can see from Eq. (1), the responsivity can be increased by decreasing the volume or by lowering the electron temperature, while the phonon temperature


\({T}_{{\rm{ph}}}\) can be higher than \({T}_{{\rm{e}}}\). This is the major difference between our bolometer and other types, that require cooling of the entire sample. The presented here


concept of a bolometer9,12 avoids the need to cool the entire detector. We use the cooling power of NIS (normal metal—insulator—superconductor) junctions to cool the electron gas in the


absorber13,14,15,16. NIS junction-based cooling is provided by the tunneling current that flows from N to S. This consists primarily of high-energy electrons, whose removal from the absorber


causes the average electron temperature in it to be reduced. As the voltage increases, the high-energy electrons gain ability to tunnel early because there are available states in the


superconductor for them above the gap. Electron cooling serves as strong electrothermal feedback in CEBs, just as it does in TES17,18. However, there is one principle difference: the


artificial heating that occurs within a TES is replaced by effective electron cooling. We demonstrate experimentally that the cooling efficiency of our samples is high enough to ensure that


the electrons in the absorber remain below the bath temperature even at high power loads. Furthermore, we investigate the possibility of using this effect to reach the record sensitivities


of other detectors, but at higher bath temperatures. We also show that cold-electron bolometers can be a potential replacement of expensive adiabatic demagnetization refrigerators and the


cooling platforms (CP). This technology can significantly reduce the cost of future space missions. RESULTS SINGLE BOLOMETER Here we demonstrate the potential of CEB, using a receiving pixel


that is designed according to the requirements of the balloon mission OLIMPO (Osservatorio per il Lontano Infrarosso e le Microonde su Pallone Orientabile, in Italian)19. This system is


aimed at precision measurement of the spectral distortion of the cosmic microwave background (CMB) near rich galaxy clusters (the Sunyaev-Zeldovich effect) and the power spectra of diffuse


sky radiation simultaneously in four frequency bands: 150, 210, 350, and 480 GHz. In space missions the power load can be rather low (on the order of 0.1 pW per pixel) due to the absence of


atmosphere and clouds. However, balloon-borne missions can impose a power load of 30–60 pW for one pixel in the 350 GHz channel, depending on the operating mode. The accepted efficiency of


absorbtion is 50%, i.e. with regard to absorbed power, photon-noise-limited operation must be in the range of 15–30 pW. Below, we show how to design a CEB-based pixel for any desired power


load. The cold-electron-bolometer consists of a normal metal absorber, a tunnel barrier and two superconducting leads that form NIS junctions from both sides of the absorber. Coupling of


external radiation occurs through the antenna, which is connected to superconducting leads7,9. Radiation is absorbed in a normal absorber. As follows from Eq. (1) the responsivity is


inversely proportional to the absorber volume. We have fabricated bolometers with \({V}_{{\rm{N}}}\) of just \(0.02\ {\mathrm{\mu}} {{\rm{m}}}^{3}\). The small absorber volume means that the


electron gas is thermally decoupled from the phonon system, since the heat flow \({P}_{{\rm{e-ph}}}\) between electron and phonon subsystems in normal metal is described by the following


dependence20,21,22,23: $${P}_{{\rm{e-ph}}}=\Sigma {V}_{{\rm{N}}}({T}_{{\rm{e}}}^{5}-{T}_{{\rm{ph}}}^{5}).$$ (2) The smaller the volume, the more decoupled the two subsystems. This allows one


to manipulate the electron temperature in the normal absorber without affecting the phonon system. We note that the coupling constant \(\Sigma\) and the power law (2) vary by materials. For


example in24 a CEB was made using a doped silicon absorber, which has a power 6 in temperature dependence of \({P}_{{\rm{e-ph}}}\)(2). Discovery of the electron cooling effect in NIS tunnel


junctions13 has initiated a new era of on-chip cooling systems with the potential to cool from 300 to 100 mK. Two NIS tunnel junctions, connected in SINIS (superconductor-insulator-normal


metal-insulatior-superconductor) structure, provide twice more efficient cooling than a single junction14. This property of NIS junctions is used in CEBs with one important addition: besides


cooling, these junctions are used for read-out and coupling with the antenna. Such easy coupling with the antenna is possible due to one more advantage of CEB—its micron size. This allows


CEB integration into various planar antennas with frequency bands from 1 GHz to above 1 THz without external feed lines. The effect of electron cooling is explained using the energy diagram


in Fig. 1a. When the voltage applied to the NIS junction is much less than the superconductor gap, the current is suppressed. When the voltage approaches the gap, the hottest electrons above


the Fermi level in the normal metal get a probability of tunneling to the superconductor. The closer the voltage is to the gap, the more cooling power is available. A schematic


representation of a CEB can be seen in Fig. 1a, where the main quasiparticle processes are shown in dc current-biased mode. The initial process is the absorbtion of a photon by an electron


in the absorber. Then, the equilibrium temperature of the electron subsystem increases due to thermalization with other electrons. The hottest electrons tunnel to the superconductor under an


applied dc bias current, cooling the absorber. In addition, there is a heat flow from electrons to phonons in the absorber (see the characteristic times of both processes in Supplementary


Note 1 and Fig. 1). But, this heat flow is much smaller than NIS cooling, because the electrons are thermally decoupled from the phonon bath due to the tiny absorber volume. Figure 1b, c 


show a 3D model of a CEB and a SEM image of the fabricated sample. The normal absorber is made of aluminum with a thin (0.7 nm) underlayer of Fe, which destroys the superconductivity in


aluminum. The gold antenna is fabricated in the first layer (yellow). The bolometer itself is fabricated in the final step. We deposite the absorber before the superconducting electrodes as


in25, thus minimizing the absorber volume and maximizing the bolometer sensitivity. Further fabrication details are given in Methods. ARRAY DEVELOPMENT A single CEB can receive up to 0.5 pW


without saturating26. For higher power loads we combine several bolometers in one pixel in order to divide the power between them, so that each bolometer works at its highest sensitivity27.


According to our calculations, 100–200 bolometers would be optimal for typical OLIMPO power loads. In the current design we use 192 bolometers in one pixel. In all, 350-GHz radiation goes


through the standard band-pass and low-pass filters to the back-to-back horn and through the substrate to bolometers integrated into dipole antennas (see Fig. 2a). We have developed an array


of dipole antennas in the shape of a corner for the purpose of receiving both polarizations. CST Microwave Studio was used to tune the antennas to match the bolometer impedance and the


OLIMPO optical system beam shape, Fig. 2b. The shapes of the fabricated antennas are shown in Fig. 2c. Two dipole antennas are joined together at \(9{0}^{\circ }\) angle to make an element


sensitive to both vertical and horizontal polarizations. Each angular element is connected by dc-lines to its neighboring elements. The entire array is fed by only one bias current channel.


The antennas are distributed on the substrate to cover an entire Airy disc, formed by a back-to-back horn. We use multi-mode horn for three modes (first and third modes with two orthogonal


polarizations). The electrical field on the substrate for vertical polarization of modes 1 and 2 (bottom) is presented from bolometer side in Fig. 2b. Mode 1 has its maximum electric field


in the center of the array, while mode 2 has its maximum intensity closer to the side. Thus, all three modes cover the Airy spot with similar intensities and different bolometers absorb


similar portions of the available power. From the bolometer side of the substrate, a backshort is placed at a distance of 213 \({\mathrm{\mu}}\)m. EXPERIMENT The fabricated samples were


measured in a Triton 200 dry dilution cryostat under optical load from a black body (BB). The scheme of experiment is shown in Supplementary Fig. 2. The photon-noise-limited mode of


operation of the array has been observed at phonon temperatures of 200 mK and 310 mK. We have measured the bolometer array voltage response and the voltage noise at several bias points and


various BB temperatures (\({T}_{{\rm{bb}}}\)). With our experimental apparatus, the black body source is attached to a 4 K plate and can be heated up to 35 K while keeping coldest plate with


bolometers at 200 mK. It can also be heated to 46 K while keeping the bolometer plate at 310 mK. In the optical experiment the phonon temperature of the cryostat plate \({T}_{0}\) is not


always equal to that of the attached chip with bolometers. As the black body continues to be heated, microwave radiation heats the chip above \({T}_{0}\), despite the band-pass and low-pass


quasi-optical filters between the black body and the bolometers. We monitor the chip temperature with the help of an on-chip thermometer, made in the same technological cycle as the


bolometers (see the Supplementary Note 2 for more details). The overheating effect becomes visible above \({T}_{{\rm{bb}}}=20\ K\) (Supplementary Fig. 3). Thus, we see a mixed response to


the microwave power load and temperature increase at high \({T}_{{\rm{bb}}}\). The phonon temperature of the chip is given in the legend of Fig. 3a and b together with the absorbed power


\({P}_{0}\). Experimental IV-curves were fitted to the theoretical model16,8 in order to determine the absorbed power (Fig. 3a, see details in Methods). We found that the array absorbs


\({P}_{0}=28\) pW at a maximum BB temperature of 35 K and \({T}_{0}=200\) mK, and 32 pW at \({T}_{{\rm{bb}}}=46\ {\rm{K}}\) and \({T}_{0}=310\ {\rm{mK}}\). Thus, the array absorbtion


efficiency is ~ \(60 \%\). The electron temperature, responsivity (\({S}_{{\rm{V}}}\)) versus bolometer voltage and NEP versus absorbed power were deduced via fitting and are shown in Fig.


3a, b, and c, respectively, for a cryostat temperature of 200 mK. The top IV-curve corresponds to the top \({T}_{{\rm{e}}}\) curve, etc. In Fig. 3a we plot two IV-curves, obtained at


\({T}_{0}=200\ mK\), and the other at \({T}_{0}=310\ mK\). The electron temperature is shown using blue curves in the (0–15) mV voltage range within Fig. 3a. Solid curves are used when the


theoretical fit and experiment agree well and dashed curves are applied when the theory may not work. It is impossible to predict the electron temperature within our quasi-equilibrium theory


correctly near the gap due to overheating. Fig. 3a shows, that at 13 mV (operating point) the electron temperature of the absorber is below the base temperature of 200 mK even at the


highest absorbed power of 28 pW and below the base temperature of 310 mK at an absorbed power 32 pW. Despite high power loads, the CEBs work at electron temperatures that are less than the


phonon temperature. This is the first demonstration of effective electron cooling under high power loads. One can compare this to ref. 28, where a bolometer was cooled from 300 to 255 mK


without power load. NOISE EQUIVALENT POWER The noise equivalent power is the ratio of the measured voltage noise density (\(\delta V\)) to the responsivity \({S}_{{\rm{V}}}\). The bolometer


NEP consists of three components8: $$\begin{array}{l}{{\rm{NEP}}}_{{\rm{e-ph}}}^{2}=10{k}_{{\rm{B}}}\Sigma {V}_{{\rm{N}}}({T}_{{\rm{e}}}^{6}+{T}_{{\rm{ph}}}^{6}),\\


{{\rm{NEP}}}_{{\rm{NIS}}}^{2}=\partial {P}_{0}^{2}+\frac{\partial {I}^{2}}{{(\partial I/\partial V\cdot {S}_{{\rm{V}}})}^{2}}-2\frac{\partial {P}_{0}\partial I}{\partial I/\partial V\cdot


{S}_{{\rm{V}}}},\\ {{\rm{NEP}}}_{{\rm{amp}}}^{2}=\frac{\delta {V}^{2}+{(R\delta I)}^{2}}{{S}_{{\rm{V}}}^{2}}.\end{array}$$ (3) where \(V\) and \(I\) are the voltage and current through the


bolometer, \(R\) is its differential resistance and \(\delta I\) is the current noise of the amplifier. The \({{\rm{NEP}}}_{{\rm{e-ph}}}\) is the noise due to electron–phonon interaction.


\({{\rm{NEP}}}_{{\rm{NIS}}}\) is the noise of NIS contacts, composed of heat flow noise, shot noise and their correlation. The \({{\rm{NEP}}}_{{\rm{e-ph}}}\) and


\({{\rm{NEP}}}_{{\rm{NIS}}}\) terms are the undiminished intrinsic noise terms of the bolometer. Therefore we refer to their sum as “self-noise”. The amplifier noise


\({{\rm{NEP}}}_{{\rm{amp}}}\) depends on the read-out type. For our room temperature amplifiers it has current and voltage noise terms. The “total NEP” comprises the sum of the bolometer NEP


and photon NEP. The internal signal noise (the photon noise) increases as \({{\rm{NEP}}}_{{\rm{ph}}}=\sqrt{{P}_{0}hf+{P}_{0}^{2}/\delta f}\), where \({P}_{0}\) is the absorbed signal power,


\(f\) is the signal frequency, \(\delta f\) is the frequency band and \(h\) is the Planck constant32. Two terms account for the wave-particle duality of BB radiation: shot noise \(\sim


\sqrt{{P}_{0}}\) and bunching noise \(\sim {P}_{0}\). In Fig. 3d we show the different components of noise equivalent power as functions of the bolometer voltage alongside the experimental


NEP. There is good agreement between the experimental and theoretical NEPs. The photon NEP (independent of bolometer voltage) is almost twice as high as the bolometer NEP in the 6–15 mV


voltage range. This indicates that the bolometer is limited by the photon noise. This plot also demonstrates how to choose the operation point for current-biased CEBs. The desired operating


point occurs at approximately 3/4 of the gap (13 mV in this plot), where the bolometer NEP is minimized. Good agreement with the theoretical model is necessary but not sufficient to prove


that the measured noise has a photon component and that this component is significant relative to the other components. Thus, we performed an additional experiment to expose the noise


increase that occurs when optical power is applied. In this experiment the cryostat temperature was regulated such that the IV-curves with and without an optical load nearly coincided. It is


clear that the cryostat temperature must be higher without an optical load. The voltage noise levels, measured in the two cases appear to be different (Fig. 3e). Due to the similarity of


the IV-curves, the amplifier and NIS noises are nearly the same. The electron–phonon noise is small enough to be excluded from consideration. Therefore, the additional noise, which we see


with an optical load, can come only from absorbed photons. The detectors presented here are photon noise-limited. This means that the noise of the absorbed signal is higher than the total


internal noise of the detector, including the amplifier noise. This is demonstrated in Fig. 3c, where the photon and bolometer NEPs are shown versus the absorbed power. The graph starts at a


low power load of 0.3 pW. At this power the responsivity is high (Fig. 3b) but the photon noise of the incoming signal is too low and thus the total NEP is equal to the bolometer noise. At


higher power loads, the bolometer NEP increases but the photon NEP increases faster. Above 1 pW, the total NEP is determined mainly by the photon noise. We note that there are no signs of


saturation at 28 pW, which means that photon noise-limited operation continues at higher power loads than we can provide in our experimental setup. In Fig. 3–f we show a plot similar to that


in Fig. 3c, but for a cryostat temperature of 310 mK. The photon noise-limited mode starts at 10 pW of absorbed power and continues at least up to 32 pW. As can be seen in Fig. 3c and f,


the phonon temperature also increases, presumably due to absorption of the out-of-band radiation by Si chip that leaks through the filter system at high black body temperature. If sample


overheating is decreased, photon noise-limited operation continues even at higher power loads. DISCUSSION High-performance photon sensors for future astronomical instruments are typically


cooled to 100 mK or below in a dilution cryostat33,34. However, the cost and complexity of these units are an obstacle to the widespread use of 100 mK sensors. The real problem is the design


of dilution cryostats for space applications that occur in the absence of gravity. The most effective current solutions are applicable only at a temperature of 0.3 K. Our goal is to show


that cold-electron bolometers can reach the photon NEPs required for space mission optical power loads, even with 300 mK cryostats. We have designed a pixel with 192 bolometers that achieves


the best performance at power levels of 10–30 pW at 300 mK and a corresponding photon NEP of \(8\cdot 1{0}^{-17}-2\cdot 1{0}^{-16}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\). If we take one bolometer


from this array, can its NEP go beyond \({{\rm{NEP}}}_{{\rm{ph}}}=6.8\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\), corresponding to a power load of 100 fW at 350 GHz? In Fig. 4a the


calculated NEP of a single bolometer is shown with all parameters exactly as in the array. The dark NEP of one CEB is \(8\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) and the best


performance occurs at 150 fW, where the bolometer NEP appears to be \(1.7\) times larger than the photon noise. One can see that the largest NEP component in Fig. 4a, which prevents us from


reaching photon-noise-limited operation, is the amplifier noise. This is because we use an AD745 room-temperature amplifier with a high current noise of \(9\ {\rm{fA}}\ {{\rm{Hz}}}^{-1/2}\)


at 120 Hz. This term depends on the read-out type and can be lowered significantly using cold amplifiers35 or SQUIDs36. Thus, it is a technical issue that can be solved via ordinary means.


We prefer to focus on the electron–phonon and NIS noises since they are fundamental and define the real CEB sensitivity limit. We calculate these two components separately as functions of


the bolometer voltage at several power loads (see Supplementary Note 3 and Supplementary Fig. 5). We plot their minima at a voltage of \(250\ \mu {\rm{V}}\) versus power in comparison with


the photon noise term in Fig. 4b. We also add the NEP component of the cold amplifier to this plot. Its voltage noise of \(1.5\ {\rm{nV}}\ {{\rm{Hz}}}^{-1/2}\) and current noise of


\(1{0}^{-16}\ {\rm{A}}\ {{\rm{Hz}}}^{-1/2}\) are taken from35 as typical values. Furthermore, advanced sorption pump technology (for example, from Cryo Industries) can help He3 cryostats


reach 260 mK with a cooling power 5 pW. Therefore, we calculate the NEP in Fig. 4b and Supplementary Fig. 5 for a phonon temperature of 260 mK. Thus the difference between A and B of Fig. 4


represents the amplifier noise and the cryostat phonon temperature. For such parameters, the dark NEP of the CEB is \(2.5\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) and photon-limited


operation starts from 15 fW. This is the minimal NEP of a cold-electron bolometer with the current design, and can be reached in He3 cryostats with low-temperature amplifiers. We are


currently working on such a readout, whose noise is less than two natural non-decreasable noise components. Further, the sensitivity can be increased by decreasing the absorber volume to


\(0.01\ \mu {{\rm{m}}}^{3}\) or even to \(0.005\ \mu {{\rm{m}}}^{3}\), potentially reaching the spectacular level of \(1.2\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\). We can compare


this result with those from TES and KID bolometers at similar temperatures and frequency ranges. Researchers typically calculate the photon NEP from the incoming power, while we calculate


the photon NEP from the power accepted by the bolometer, which can be 50% smaller. The TES detector array, which was developed for 280 GHz37 at 300 mK has an NEP of \(2.6\cdot 1{0}^{-17}\


{\rm{W}}\ {{\rm{Hz}}}^{-1/2}\). A KID at 150 GHz38 has a dark NEP of \(2\cdot 1{0}^{-17}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) at 120 mK with photon limited operation from 1 pW. A similar KID


designed for \(80-120\) GHz and presented in ref. 39 has a dark NEP of \(2\cdot 1{0}^{-17}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) at a bath temperature of 100 mK. In addition, while KIDs have


become more popular, the most prominent NEP values are typically reported for frequencies on the order of 1.5 THz and low power loads because superconductive absorbing elements impose


limitations on low frequencies. See for example ref. 6. Unlike with KIDs, the radio frequency signal is absorbed by the normal metal in CEBs. This allows a broad frequency range of


operation, from several GHz to substantially above 1 THz. Other shortcomings of both TESs and KIDs is their large surface and ability to couple to a substrate/spider-web, which is important


for balloon and space applications. It is known that a large fraction of Planck data is unusable due to cosmic rays that result in noisy glitches. For example, in a TES with a spider-web


membrane, the absorber volume is usually on the order of \(0.01\ {{\rm{mm}}}^{3}\), while the CEB absorber volume is only \(0.02\ \mu {{\rm{m}}}^{3}\). The combination of a large volume


difference and a weak electron–phonon coupling results in CEB cosmic rays immunity40 that is outstanding in comparison to TESs and KIDs. Cosmic rays that hit the substrate do not reach the


absorber, which is the only sensitive element of the CEB. Thus, a cold-electron bolometer with a dark NEP of \(2.5\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) at 260 mK and a proper


read-out system reaches sensitivities not available with KID or TES devices. Thus, it can satisfy modern requirements and balance the three main concerns of future space and balloon


missions: cooling system, detectors and cost. We should note that there is an alternative method of developing cryogenic detectors. One can decrease the phonon temperature of the receiver


using the electron cooling effect, producing a cooling platform (CP)15,41,42. However, this concept has several disadvantages and cooling becomes significantly less effective as the


temperature decreases43. This results in a minimum cooling temperature of ~200 mK from a 300 mK base temperature. Now let us discuss the difference between CPs and CEBs. CP-based electron


cooling is not effective because the system must overcome the small electron–phonon thermal conductance and Kapitsa resistance twice. One must cool membrane electrons, membrane phonons


(weakly coupled to the electrons), detector phonons, and detector electrons. In this case, the cooling efficiency decreases significantly by the second cooling stage, during which the


membrane electrons cool phonons as they are thermally decoupled. Moreover, the e-ph conductivity weakens with \({T}^{4}\) as the temperature decreases, making further cooling more difficult.


The CP efficiency (the ratio of cooling power to dissipated power \({P}_{{\rm{COOL}}}/IV\)) is considerably less than \(1 \%\). The data used to estimate the cooling efficiency is taken


from43: the cooling power of one pair of NIS junctions is 1 nW, the input power of the cooler is about 100 nW and the total power dissipated in the membrane surroundings is \(1\ \mu


{\rm{W}}\). Unlike with CP, CEB uses weak e-ph thermal conductance to protect the absorber from leakage of heat to phonons. Therefore, direct electron cooling of the absorber through the


tunnel junctions is highly effective and any cooling leads to a decreased e-ph thermal conductance and improved absorber thermal isolation. The efficiency of CEB cooling is ~\(40 \%\). In


addition, the thin-legged suspended membrane used to achieve thermal isolation of the cooler from a substrate in CP is fragile. In contrast, CEB is a rigid structure on a planar Si


substrate. Furthermore, CP commonly uses a large cooling current to maximaze the cooling power. This creates problems with hot quasiparticles in the superconductor and consequently leads to


lower cooling efficiencies. A CEB has fewer hot quasiparticles due to its smaller cooling current because the cooling power need not be maximized since the system cools only electrons in a


small absorber. Therefore, the CEB represents an effective solution that is scalable to the desired power level and able to reach low NEP values even at a working temperature of 0.3 K. It


also offers high cosmic ray immunity, which is crucial for space applications. Thus, a mm/IR bolometer that operates at an electron temperature that is less than the phonon temperature under


a high power load is presented for the first time. Electron cooling provides strong electrothermal feedback as in TES but with substantial difference: the artificial heating of TES is


replaced with strong electron cooling. Due to effective electron self-cooling of the absorber, photon-noise-limited operation of a 2D array of CEBs has been achieved at 310 mK. The resulting


2D array of CEBs represents a single pixel for 350 GHz channel of the OLIMPO balloon experiment. We have shown that electron temperature in a CEB array can go from 310 to 120 mK. This study


suggests that CEBs with internal self-cooling are potential candidates to form the basis of a core technology with ultimate parameters for advanced radio astronomy projects that must avoid


dilution refrigerators. With a proper readout, they could potentially reach the spectacular NEP of \(1.2\cdot 1{0}^{-18}\ {\rm{W}}\ {{\rm{Hz}}}^{-1/2}\) at 260 mK. Therefore, this can solve


the main problem of the COrE space mission that was not accepted by the European Space Agency from 2007 due to necessity to find compromise between sensitivity, cryogenics and cost. METHODS


TECHNOLOGY AND MATERIALS Samples were fabricated on silicon wafers using three steps: Si wafer etching, antenna fabrication and bolometer fabrication. Numerical simulations have shown that


absorption is maximized with a substrate thickness of \(127\ \mu {\rm{m}}\). We chose \(350\ \mu {\rm{m}}\) substrates and etched the area covered by Airy spot down to the required \(127\


\mu {\rm{m}}\) from the back side. The antennas and bolometers were fabricated on the front side of the wafer. The antennas were fabricated using optical lithography and electron beam


evaporation of three metals: 10 nm of Ti for adhesion, 200 nm of Au and 20 nm of Pd for good contact with Al. The bolometer mask was formed via electron beam lithography. The bolometers were


made using a self-aligned shadow evaporation technique. First a normal absorber made from 14 nm of Al with a 1 nm underlayer of Fe was evaporated at zero angle. Then, the tunnel barrier was


formed via oxidation at 10 mbar. Next, 60 nm and 70 nm thick superconducting Al electrods were evaporated at angles of +45 and −45 degrees, respectively. This method differed from that


provided by ref. 25 with regard to fabricating normal Al from superconducting Al. HEAT BALANCE MODEL AND FITTING OF EXPERIMENTAL RESULTS Fitting was achieved by solving heat balance


equations with parameters that described the experimental IV-curves well. The absorptive element in the CEB, the electron gas of a normal metal, was described well by the heat balance


equation $${P}_{{\rm{N}}}+{P}_{0}+2\beta {P}_{{\rm{S}}}={P}_{{\rm{e-ph}}}+2{P}_{{\rm{COOL}}}.$$ (4) There were three heating sources in the normal absorber: Joule heat \({P}_{{\rm{N}}}\) in


the absorber due to its finite resistivity, absorbed radiation power \({P}_{0}\), and \({P}_{{\rm{S}}}\) – the net power dissipated in the superconducting electrode. The power flow from


backtunneling of quasiparticles in the superconducting electrode to the normal absorber through the absorption of phonons emitted by quasiparticle recombination was represented by \(2\beta


{P}_{{\rm{S}}}\). There was also one cooling source, the cooling power of the NIS junction \({P}_{{\rm{COOL}}}\). The electron–phonon heat exchange \({P}_{{\rm{e-ph}}}\) can either be


cooling or heating source depending on whether \({T}_{{\rm{e}}}\) is larger than \({T}_{{\rm{ph}}}\) or smaller. To increase the accuracy of the model, we also used the equation for


quasiparticles in superconducting electrodes, which exchange the heat with phonons and normal metal electrons $$\epsilon (1-\beta){P}_{{\rm{S}}}={P}_{{\rm{e-ph,S}}}.$$ (5) The superconductor


quasiparticles were heated by the power, transferred from the normal metal \((1-\beta){P}_{{\rm{S}}}\). Part of this power was moved away from the tunnel junction or dissipated in the


phonon system21, but some fraction \(\epsilon\) of this power stayed in the quasiparticle system (\(\epsilon < 1\) is a fitting parameter). \({P}_{{\rm{e-ph,S}}}=0.98{\Sigma


}_{{\rm{S}}}{V}_{{\rm{S}}}({T}_{{\rm{S}}}^{5}-{T}_{{\rm{ph}}}^{5}){e}^{-\Delta ({T}_{{\rm{S}}})/{k}_{{\rm{B}}}{T}_{{\rm{S}}}}\) was the electron–phonon coupling in the superconductor22. The


problem of superconducting electrodes overheating arose at high voltages (near the gap), where our model is not particularly accurate. The accuracy (and the complexity) of the model could be


increased by considering the spatial dependence of the temperature in the superconducting electrodes. However, we did not use this approach since we worked below the gap. The phonons in


both normal metal and the superconductor were intended to remain at the bath temperature at all times. The phenomenological parameter \(\beta\) reflected the fact that the heat removed from


the absorber via electron tunneling can typically return to the absorber through the phonons, and in an ideal case \(\beta =0\). In order to prevent this heat from returning, the hot


electrons in superconductor must be moved away from the tunnel barrier efficiently. For this purpose we designed a double stock at both sides of the tunnel junction and increased the


superconducting electrode thickness and width16 to provide more volume for quasiparticle dissipation. Thus, we managed to decrease \(\beta\) from 0.35 in ref. 29 to 0.06. A further decrease


can be achieved via implementation of normal metal traps30,31, that require one additional technological layer. The investigated sample represented an


\({\rm{Al}}-{{\rm{Al}}}_{2}{{\rm{O}}}_{3}-{\rm{AlFe}}-{{\rm{Al}}}_{2}{{\rm{O}}}_{3}-{\rm{Al}}\) SINIS structure, where the superconductivity of the Al absorber was suppressed by a thin Fe


layer underneath Al. The following parameters were measured directly: normal array resistance \({R}_{{\rm{n}}}\) = 37.6 kOhm (Supplementary Fig. 4), volume of the absorber in one bolometer


\(0.02\ \mu {{\rm{m}}}^{3}\), critical temperature of the Al electrodes 1.244 K, absorber resistance 50 Ohm. The phonon temperature of the chip was measured using an on-chip thermometer,


made of NIS tunnel junctions. The fitting parameters were: \(\Sigma =1.3\ {\rm{nW}}\ {{\rm{K}}}^{-5}\mu {{\rm{m}}}^{-3}\), effective volume of the superconducting electrode \(2.5\ \mu


{{\rm{m}}}^{3}\), \({\Sigma }_{{\rm{S}}}=0.45\ {\rm{nW}}\ {{\rm{K}}}^{-5}\mu {{\rm{m}}}^{-3}\), \(\beta =0.06\), leakage resistance of the array 300 MOhm, and \(\epsilon =0.003\). The


absorbed power varied from 0.3 to 32 pW depending on the black body temperature. ELECTRO-MAGNETIC SIMULATIONS Electro-magnetic simulations of the entire system were performed to maximize the


absorption efficiency. The system consisted of a substrate with an array of dipole antennas with bolometers, a backshort from the front side of the wafer, and a triple-mode waveguide horn


designed to form a beam matched with a telescope beam. The source of excitation was a waveguide port at the far end of the horn. First, the radiation went through the horn and the


half-wavelength substrate to the bolometers, where part of it was absorbed and part went to the backshort to be reflected back to the bolometers. The substrate thickness and distance to the


backshort were tuned so that the transmitted and reflected waves formed a standing wave. Thus, the wave energy stayed near the bolometers until it was absorbed. We used 192 antennas to cover


the 3 mm diameter Airy spot: 96 for vertical and 96 for horizontal polarizations. The length of one dipole was \(130\ \mu {\rm{m}}\). The impedance of each dipole was 50 Ohms. With such


parameters, we achieved the absorption efficiencies of 70\(\%\) in simulations and 60\(\%\) in experiments. We started by simulating of the noise properties of the CEB array in the framework


of the heat balance model developed in16,21 and 8. In this model, electron subsystem thermal equilibrium was assumed so that the Fermi-Dirac distribution could be used. The model is valid


for a broad range of parameters, until operating conditions become highly non-equilibrium (low temperatures or high currents). In the present article, the operating point is always in a


region where the Fermi-Dirac distribution is a good approximation. NOISE FROM READOUT ELECTRONICS The pixel impedance at the operating point must be below the input impedance of the


amplifiers to minimize the noise introduced by the readout electronics. We use the JFET room temperature amplifiers AD745. They have voltage noise \(5\ {\rm{nV}}\ {{\rm{Hz}}}^{-1/2}\) and


current noise \(9\ {\rm{fA}}\ {{\rm{Hz}}}^{-1/2}\) at 120 Hz, making the input resistance around 500 MOhm. The power load in the OLIMPO mission per pixel is 10 pW - 60 pW, which


significantly exceeds the power that one CEB can accept without going into saturation. Therefore, we use several bolometers in one pixel, distributing the power load so that each bolometer


receives no more than 0.3 pW. In total, 192 bolometers are used in the array. A single bolometer of the considered design has a resistance of 88 kOhm at the operating point at 300 mK without


power load and 26 kOhm at maximum power load of \({P}_{{\rm{in}}}=0.3\ {\rm{pW}}\). In order to match the impedance of the array with 500 MOhm, we connect the bolometers with each other


both sequentially and parallelly. For this project, 48 serial connections and four parallel connections are used. A complete analysis of noise properties was performed in the heat balance


model. Along with the amplifier noise we accounted for intrinsic noise from bolometers and external photon noise. DATA AVAILABILITY The data that support the findings of this work are


available from the corresponding author upon reasonable request. REFERENCES * Crittenden, R., Davis, R. L. & Steinhardt, P. J. Polarization of the microwave background due to primordial


gravitational waves. _Astrophys. J. Lett._ 417, L13 (1993). Article  ADS  Google Scholar  * Seljak, U. & Zaldarriaga, M. Signature of gravity waves in the polarization of the microwave


background. _Phys. Rev. Lett._ 78, 2054 (1997). Article  ADS  Google Scholar  * Day, P. et al. Distributed antenna-coupled TES for FIR detector arrays. _J. Low. Temp. Phys._ 151, 477–482


(2008). Article  ADS  Google Scholar  * Beyer, A. D. et al. Effect of Mo/Cu superconducting bilayer geometry on ultra-sensitive transition-edge sensor performance. _IEEE Trans. On Appl.


Supercond._ 23, 2100104 (2013). Article  Google Scholar  * Khosropanah, P. et al. Low noise transition edge sensor (TES) for the SAFARI Instrument on SPICA. in _Proc. SPIE 7741, Millimeter,


Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V_, 77410L (2010). * Visser, P. J., Baselmans, J. J. A., Bueno, J., Llombart, N. & Klapwijk, T. M.


Fluctuations in the electron system of a superconductor exposed to a photon flux. _Nat. Comm._ 5, 3130 (2014). Article  ADS  Google Scholar  * Kuzmin, L. On the concept of a hot-electron


microbolometer with capacitive coupling to the antenna. _Physica B: Condensed Matter_. 2129, 284–288 (2000). Google Scholar  * Golubev, D. & Kuzmin, L. Nonequilibrium theory of a


hot-electron bolometer with normal metal-insulator-superconductor tunnel junction. _Journ. Appl. Phys._ 89, 6464 (2001). Article  ADS  Google Scholar  * Kuzmin, L. Optimization of the


Hot-Electron Bolometer for Space Astronomy. In: (eds Pekola, J., Ruggiero, B. & Silvestrini P.). _The International Workshop on Superconducting Nano-Electronics Devices_, P. 145–154


(Springer, Boston 2002). * Kuzmin, L. Ultimate cold-electron bolometer with strong electrothermal feedback. _Proceedings of SPIE_ 5498, 349 (2004). Article  ADS  Google Scholar  * Giazotto,


F., Heikkila, T. T., Luukanen, A., Savin, A. M. & Pekola, J. P. Opportunities for mesoscopics in thermometry and refrigeration: physics and applications. _Rev. Mod. Phys._ 78, 217


(2006). Article  ADS  Google Scholar  * Kuzmin, L., Agulo, I., Fominsky, M., Savin, A. & Tarasov, M. Optimization of the electron cooling by SIN tunnel junctions. _Supercon. Sci.


Technol._ 17, S400 (2004). Article  ADS  Google Scholar  * Nahum, M., Eiles, T. M. & Martinis, J. M. Electronic micro-refrigerator based on a NIS tunnel junction. _Appl. Phys. Lett._ 65,


3123 (1994). Article  ADS  Google Scholar  * Leivo, M. M., Pekola, J. P. & Averin, D. V. Efficient Peltier refrigeration by a pair of NIS junctions. _Appl. Phys. Lett._ 68, 1996 (1996).


Article  ADS  Google Scholar  * Manninen, A. J., Leivo, M. M. & Pekola, J. P. Refrigeration of a dielectric membrane by SINIS tunneling. _Appl. Phys. Lett._ 70, 1885 (1997). Article 


ADS  Google Scholar  * Fisher, P. A., Ullom, J. N. & Nahum, M. High-power on-chip microrefrigerator based on a normal-metal/insulator/superconductor tunnel junction. _Appl. Phys. Lett._


74, 2705 (1999). Article  ADS  Google Scholar  * Irwin, K. An application of electrothermal feedback for high resolution cryogenic particle detection. _Appl. Phys. Lett._ 66, 1998 (1995).


Article  ADS  Google Scholar  * Lee, A., Richards, P., Nam, S., Cabrera, B. & Irwin, K. A superconducting bolometer with strong electrothermal feedback. _Appl. Phys. Lett._ 69, 1801


(1996). Article  ADS  Google Scholar  * Masi, S. et al. OLIMPO. _Mem. S. It_ 79, 887 (2008). ADS  Google Scholar  * Wellstood, F. C., Urbina, C. & John, C. Hot-electron effects in


metals. _Phys. Rev. B_ 49, 5942 (1994). Article  ADS  Google Scholar  * Ullom, J. N. & Fisher, P. A. Quasiparticle behavior in tunnel junction refrigerators. _Physica B_. 2036, 284–288


(2000). Google Scholar  * Timofeev, A. V. et al. Recombination-limited energy relaxation in a bardeen-cooper-schrieffer superconductor. _Phys. Rev. Lett._ 102, 017003 (2009). Article  ADS 


Google Scholar  * Muhonen, J., T., Meschke, M. & Pekola, J. P. Micrometre-scale refrigerators. _Rep. Prog. Phys._ 75, 046501 (2012). Article  ADS  Google Scholar  * Brien, T. L. R. et


al. A strained silicon cold electron bolometer using Schottky contacts. _Appl. Phys. Lett._ 105, 043509 (2014). Article  ADS  Google Scholar  * Clark, A. M., Williams, A., Ruggiero, S. T.,


van den Berg, M. L. & Ullom, J. N. Practical electron-tunneling refrigerator. _Appl. Phys. Lett._ 84, 625 (2004). Article  ADS  Google Scholar  * Kuzmin, L. S. A Parallel/Series Array of


Cold-Electron Bolometers with SIN Tunnel Junctions for Cosmology Experiments. _IEEE/CSC Eur. Supercond. News Forum_. 3, ST23, 1–9 (2008). * Kuzmin, L. An array of cold-electron bolometers


with SIN tunnel junctions and JFET readout for cosmology instruments. _J.Phys.: Conf. Se._ 97, 012310 (2008). Google Scholar  * Silverberg, R. F. et al. Superconducting transition-edge


sensor bolometers with integrated electron-tunneling refrigerators. _J. Low. Temp. Phys._ 151, 489–494 (2008). Article  ADS  Google Scholar  * Gordeeva, A. V. et al. Observation of photon


noise by cold-electron bolometers. _Appl. Phys. Lett._ 110, 162603 (2017). Article  ADS  Google Scholar  * O’Neil, G. C., Lowell, P. J., Ullom, J. N., Underwood, J. M. Measurement and


modeling of a large-area normal-metal/insulator/superconductor refrigerator with improved cooling. _Phys. Rev. B_. 85, 134504 (2012). * Nguyen, H. Q. et al. Trapping hot quasi-particles in a


high-power superconducting electronic cooler. _New J. Phys._ 15, 085013 (2013). Article  ADS  Google Scholar  * Lamarre, J. M. Photon noise in photometric instruments at far-infrared


andsubmillimeter wavelengths. _Appl. Opt._ 25, 870 (1986). Article  ADS  Google Scholar  * Lamarre, J. M. et al. Use of high sensitivity bolometers for astronomy: Planck high frequency


instrument. _AIP Conference Proceedings_. 605, 571 (2002). Article  ADS  Google Scholar  * Audley, M. D. et al. Optical performance of prototype horn-coupled TES bolometer arrays for SAFARI.


in _Proc. SPIE 9914, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VIII_, 991408 (2016). * Yvon, D. & Sushkov, V. Low noise cryogenic


electronics: preamplifier configurations with feedback on the bolometer. _IEEE Trans. On Nucl. Sci._ 47, 428 (2000). Article  ADS  Google Scholar  * Dobbs, M. A. et al. Frequency multiplexed


superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements. _Rev. Sci. Instrum._ 83, 073113 (2012). Article  ADS  Google


Scholar  * Hubmayr, J. et al. Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne polarimeter SPIDER. in _Proc. SPIE 9914, Millimeter, Submillimeter, and Far-Infrared


Detectors and Instrumentation for Astronomy VIII_, 99140 (2016). * McCarrick, H. et al. Design and performance of dual-polarization lumped-element kinetic inductance detectors for


millimeter-wave polarimetry. _A&A_ 610, A45 (2018). Article  ADS  Google Scholar  * Catalano, A. Bi-layer kinetic inductance detectors for space observations between 80–120 GHz.


_A&A_ 580, A15 (2015). Article  ADS  Google Scholar  * Salatino, M., de Bernardis, P., Kuzmin, L. S., Mahashabde, S. & Masi, S. Sensitivity to cosmic rays of cold electron bolometers


for space applications. _J. Low Temp. Phys._ 176, 323 (2014). ADS  Google Scholar  * Miller, N. A. et al. High resolution x-ray transition-edge sensor cooled by tunnel junction


refrigerators. _Appl. Phys. Lett._ 92, 163501 (2008). Article  ADS  Google Scholar  * Vercruyssen, N. et al. Substrate-dependent quasiparticle recombination time in superconducting


resonators. _Appl. Phys. Lett._ 99, 062509 (2011). Article  ADS  Google Scholar  * Nguyen, H. Q., Meschke, M. & Pekola, J. P. A robust platform cooled by superconducting electronic


refrigerators. _Appl. Phys. Lett._ 106, 012601 (2015). Article  ADS  Google Scholar  Download references ACKNOWLEDGEMENTS We would like to thank M. Tarasov for help in the sample


fabrication, D. Golubev for useful discussions and E. Skorokhodov for making SEM image of the sample. The work is supported by the Swedish National Space Board, SNSB, and Russian Science


Foundation (Project No. 16-19-10468). The samples were fabricated in the Chalmers Nanotechnology Center. The facilities of the Center of Cryogenic Nanoelectronics of NNSTU and Common


Research Center"Physics and technology of micro- and nanostructures"of IPM RAS were used. Open access funding provided by Chalmers University of Technology. AUTHOR INFORMATION


AUTHORS AND AFFILIATIONS * Chalmers University of Technology, 41296, Gothenburg, Sweden L. S. Kuzmin * Nizhny Novgorod State Technical University n.a. R.E. Alekseev, GSP-41, Nizhny Novgorod,


603950, Russia L. S. Kuzmin, A. L. Pankratov, A. V. Gordeeva, V. O. Zbrozhek, V. A. Shamporov, L. S. Revin & A. V. Blagodatkin * Institute for Physics of Microstructures of RAS,


GSP-105, Nizhny Novgorod, 603950, Russia A. L. Pankratov, A. V. Gordeeva, V. A. Shamporov, L. S. Revin & A. V. Blagodatkin * Dipartimento di Fisica, Universit‘a La Sapienza, P.le A. Moro


2, I-00185, Roma, Italy S. Masi & P. de Bernardis Authors * L. S. Kuzmin View author publications You can also search for this author inPubMed Google Scholar * A. L. Pankratov View


author publications You can also search for this author inPubMed Google Scholar * A. V. Gordeeva View author publications You can also search for this author inPubMed Google Scholar * V. O.


Zbrozhek View author publications You can also search for this author inPubMed Google Scholar * V. A. Shamporov View author publications You can also search for this author inPubMed Google


Scholar * L. S. Revin View author publications You can also search for this author inPubMed Google Scholar * A. V. Blagodatkin View author publications You can also search for this author


inPubMed Google Scholar * S. Masi View author publications You can also search for this author inPubMed Google Scholar * P. de Bernardis View author publications You can also search for this


author inPubMed Google Scholar CONTRIBUTIONS L.S.K. led the project, devised the main conceptual ideas and contributed to the design of samples and interpretation of the results. A.L.P.


designed the electrodynamic model of the antenna system and performed the simulations, took an active part in measurements and the improvement of noise properties of the system, getting the


ultimate performance of bolometers. A.V.G. took part in electrodynamic simulations, carried out the experiment and compared the data with a theory. V.O.Z. carried out the experiment and


contributed to sample preparation. V.A.S. performed the analytic calculations of the noise properties of the bolometer array and contributed into the design of samples. L.S.R. performed


comparable analysis of the experimental data. S.M. formulated statement of the problem for the OLIMPO project,contributed to the concept of the readout system for arrays of bolometers and


assisted in realization of electronics. P.de.B. developed the concept of the telescope, formulated requirements for bolometer arrays, and took part in interpretation of the results. A.V.B.


participated in measurements. All authors discussed the results and contributed to the final paper. CORRESPONDING AUTHOR Correspondence to L. S. Kuzmin. ETHICS DECLARATIONS COMPETING


INTERESTS The authors declare no competing interests. ADDITIONAL INFORMATION PUBLISHER’S NOTE: Springer Nature remains neutral with regard to jurisdictional claims in published maps and


institutional affiliations. SUPPLEMENTARY INFORMATION SUPPLEMENTARY MATERIALS PEER REVIEW FILE RIGHTS AND PERMISSIONS OPEN ACCESS This article is licensed under a Creative Commons


Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original


author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the


article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use


is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit


http://creativecommons.org/licenses/by/4.0/. Reprints and permissions ABOUT THIS ARTICLE CITE THIS ARTICLE Kuzmin, L.S., Pankratov, A.L., Gordeeva, A.V. _et al._ Photon-noise-limited


cold-electron bolometer based on strong electron self-cooling for high-performance cosmology missions. _Commun Phys_ 2, 104 (2019). https://doi.org/10.1038/s42005-019-0206-9 Download


citation * Received: 16 January 2019 * Accepted: 14 August 2019 * Published: 03 September 2019 * DOI: https://doi.org/10.1038/s42005-019-0206-9 SHARE THIS ARTICLE Anyone you share the


following link with will be able to read this content: Get shareable link Sorry, a shareable link is not currently available for this article. Copy to clipboard Provided by the Springer


Nature SharedIt content-sharing initiative